Frymaster SinBaD Series warranty Problem, Probable Causes, Corrective Action

Models: SinBaD Series

1 13
Download 13 pages 30.78 Kb
Page 13
Image 13

PROBLEM

Probable Causes

Corrective Action

 

B. If the erratic batch weights are

B. Verify that the dispensing chute is

 

occurring consistently, the probable

properly positioned on the load cell

Continued from

cause is a misaligned component.

arms, that the deflector is properly

 

positioned in the hopper, and that

previous page.

 

the hopper is fully seated behind

 

 

the locking rim on the cradle

 

 

assembly.

 

If one of the above actions does not correct

the problem, there may be a problem

 

with the programmed weight settings or the load cell. Call FASC.

 

A. Unit was not in STANDBY mode

A. The CLEAN mode can only be

 

when attempt was made to enter

selected when the unit is in the

 

CLEAN mode.

STANDBY mode.

UNIT WILL NOT GO

 

Press the RUN Switch once to

INTO CLEAN MODE.

 

 

place the unit in the STANDBY

 

 

 

 

mode, and then press the CLEAN

 

 

Switch.

 

If the above action did not correct the problem, call FASC.

3-3

Page 13
Image 13
Frymaster SinBaD Series warranty Problem, Probable Causes, Corrective Action, If one of the above actions does not correct