PROBLEM | Probable Causes | Corrective Action |
| B. If the erratic batch weights are | B. Verify that the dispensing chute is |
| occurring consistently, the probable | properly positioned on the load cell |
Continued from | cause is a misaligned component. | arms, that the deflector is properly |
| positioned in the hopper, and that | |
previous page. |
| the hopper is fully seated behind |
|
| the locking rim on the cradle |
|
| assembly. |
| If one of the above actions does not correct | the problem, there may be a problem |
| with the programmed weight settings or the load cell. Call FASC. | |
| A. Unit was not in STANDBY mode | A. The CLEAN mode can only be |
| when attempt was made to enter | selected when the unit is in the |
| CLEAN mode. | STANDBY mode. |
UNIT WILL NOT GO |
| Press the RUN Switch once to |
INTO CLEAN MODE. |
| |
| place the unit in the STANDBY | |
|
| |
|
| mode, and then press the CLEAN |
|
| Switch. |
| If the above action did not correct the problem, call FASC. |