Frymaster SinBaD Series Problem, Probable Causes, Corrective Action, Operator Troubleshooting

Models: SinBaD Series

1 13
Download 13 pages 30.78 Kb
Page 12
Image 12
3.2Operator Troubleshooting

PROBLEM CAUTION

When replacing the dispensing chute, ensure that the door hinge screws are to the right as you face

the unit.

3.2Operator Troubleshooting

The operator troubleshooting guides that follow are intended to help operators resolve routine problems that may be encountered during operation of the unit.

PROBLEM

Probable Causes

Corrective Action

UNIT WILL NOT

A. ON/OFF rocker switch is in OFF

A. Place rocker switch in the ON

POWER UP or

position.

position.

NOTHING HAPPENS

B. Unit is not plugged in.

B. Plug unit in.

WHEN “RUN” MODE

C. Main circuit breaker is tripped.

C. Reset circuit breaker.

IS SELECTED.

If the problem is not corrected by one of the above actions, call FASC.

 

A. Dispensing chute is not properly

A. Reposition dispensing chute so that

RUN SWITCH

positioned on the load cell arms.

is firmly seated on the load cell

 

arms. Turn the unit OFF then back

INDICATOR AND

 

 

ON using the ON/OFF rocker

PROGRAM SWITCH

 

 

switch. Press the RUN switch

INDICATOR ARE

 

Simultaneous flashing of the run switch indicator and program switch indicator

FLASHING.

 

signals that the unit is not properly zeroed. If the problem is not corrected by the

 

above action, call FASC.

 

 

A. Dispensing chute is full.

A. If the dispense chute has been

 

 

loaded but not dispensed, nothing

NOTHING HAPPENS

 

will happen until the batch has been

 

dispensed, except when the batch

WHEN A BATCH

 

 

weight is increased. Insert a basket

SIZE SELECTOR IS

 

 

into the dispensing well to dispense

PRESSED.

 

 

batch.

 

 

 

B. Unit is not in RUN mode.

B. Press RUN switch once.

 

If one of the above actions did not correct

the problem, call FASC.

 

A. The load cell may not have been

A. Check the hopper to verify that the

 

satisfied within 30 seconds, normally

deflector is properly positioned. If

DISPENSE DOOR

because the hopper is empty or the

there are fries in the hopper, verify

fries have “bridged”.

that there is no bridging. If the

DOES NOT OPEN

 

hopper is empty, reload the hopper.

WHEN BASKET IS

 

 

Press the PROGRAM switch once

INSERTED.

 

 

to place the unit back into opera-

 

 

 

 

tion.

 

If the above action did not correct the problem, call FASC.

 

A. If the erratic batch weights are

A. Exercise care when working around

ERRATIC BATCH

occurring only occasionally, the

the unit to avoid bumping or jarring

probable cause is bumping, jarring,

it while it is in operation. Ensuring

WEIGHTS ARE

and/or unusual vibration (such as

that the unit is not touching

BEING DISPENSED.

caused by inserting a basket with

adjacent walls, and placing the unit

 

undue force, the slamming of a freezer

on a rubber mat will reduce the

 

door, or the passing of a nearby train).

effect of environmental vibrations.

3-2

Page 12
Image 12
Frymaster SinBaD Series warranty Problem, Probable Causes, Corrective Action, Operator Troubleshooting