This fryer must be installed with a 6-inch (150-mm) clearance at both sides and back when installed adjacent to combustible construction. No clearance is required when installed adjacent to non-combustible construction. A minimum of 24-inches (600-mm) clearance should be provided at the front of the fryer.

SUPER RUNNER SERIES ELECTRIC FRYERS

CHAPTER 1: INSTALLATION INSTRUCTIONS

CLEARANCE AND VENTILATION

This fryer must be installed with a 6-inch (150-mm) clearance at both sides and back when installed adjacent to combustible construction. No clearance is required when installed adjacent to non-combustible construction. A minimum of 24-inches (600-mm) clearance should be provided at the front of the fryer.

INSTALLATION

For units equipped with legs: Lift the unit and move it into its final position. Do not drag or push the fryer into position. Doing so may damage the legs. Level the unit front to back and side to side. If the fryer is not level, the unit will not function efficiently.

A.Adjust leg height with an adjustable or 1-1/16-inch (27-mm) open-end wrench by turning the hexagon-shaped foot on the bottom of the leg. NOTE: The foot is for minor leg height adjustment only. Do not adjust outward more than ¾-inch(19-mm).

B.When leveling the unit, the leg body should be held firmly to keep the leg from bending or rotating while turning the foot to the required height.

For units equipped with casters: Roll the unit into its final position and lock the front casters.

When the fryer is leveled in its final position, install the restraints provided with the unit to limit its movement so that it does not depend on or transmit stress to the electrical conduit or connection. Install the restraints in accordance with the provided instructions (see illustration below). If the restraints are disconnected for service or other reasons, they must be reconnected before the fryer is used.

1.3 Power Requirements

 

Use copper wire ONLY suitable for at least 194°F (90°C)

 

MODEL

 

VOLTAGE

PHASE

WIRE

MINIMUM WIRE

AMPS

 

SIZE

 

 

SERVICE

 

(per leg)

 

 

 

 

AWG

mm

 

 

 

 

 

 

14 kW

 

208

Single

3

4

(5.83)

68

14 kW

 

208

3

3

8

(4.11)

39

14 kW

 

240

Single

3

4

(5.19)

59

14 kW

 

240

3

3

8

(3.26)

34

14 kW

 

230/400

3

4

6

(4.11)

21

Manual background DANGER

The electrical power supply for this appliance MUST be the same as indicated on the rating and serial

number plate located on the inside of the fryer door.

Manual background DANGER

This appliance MUST be connected to the voltage and phase specified on the rating and serial

number plate located inside the fryer door.

Manual background DANGER

All wiring connections for this appliance MUST be made in accordance with the wiring diagrams

furnished with the equipment. Wiring diagrams are located inside the fryer door.