Confidential: FUJIFILM Service Center Use Only
XF56mmF1.2 R Simple Manual
-For Repair Centers without the Lens Repair Traini ng-
SAFETY CHECK-OUT
During repair and safety checking, conduct the followings.
1. Check if there are unsoldered or poorly
soldered connections. Check the entire
board surface for solder splasher and
bridges.
2. Check the inter-board wiring to ensure that
no wires are “pinched” or contact high-
wattage resistors.
3. Look for unauthorized replaced parts,
particularly transistors that were installed in
a previous repair. Point this out to a
customer and recommend replacing with
authorized parts.
4. Look for parts which, though functioning,
signs of deterioration. Point this out to a
customer and recommend replacing with
new parts.
5. Check the B + voltage to see if it is the
correct value.
6. Check leakage current see if exposed parts
are insulated from power supply before
returning a camera to a customer.
7.
8.
CAUTION:
FOR PROTECTION
AGAINST FIRE HAZARD,
REPLACE ONLY WITH
SAME TYPE 2.5 AMPERES
125V/250V FUSE.
ATTENTION:
AFIN D’ASSURER UNE
PROTECTION
PERMANENTE CONTRE
LES RISQUES D'INCENDIE,
REMPLACER
UNIQUEMENT PAR UN
FUSIBLE DE MEME, TYPE
2.5 AMPERES, 125/250
VOLTS.
WARNING:
TO AVOID THE ELECTRIC
SHOCK, BE CAREFUL TO
TOUCH THE PARTS.
RISK OF FIRE-
REPLACE FUSE
A
S MARKED
2.5A 125V
2.5A 125V
WARNING!
HIGH VOLTAGE
2