SCSI/Host RAID-Konfigurationsprogramm

Leistungsmerkmale

Standardeinstellungen im Menü Configure/View SCSI Controller Settings

SCSI-Bus Interface Definitions

Standardeinstellung

SCSI-Controller ID

7

SCSI-Controller Parity

Enabled

SCSI-Controller Termination

Enabled

Additional Options

Standardeinstellung

Boot Device Configuration

Press <Enter>

Single Image

 

Master SCSI-Controller

AIC-7902 at slot 00 00:04:00

Select SCSI peripheral from which to boot

 

Boot SCSI-Controller

AIC-7902 at slot 00 00:04:00

Boot SCSI ID

0

Boot LUN Number*

0

SCSI Device Configuration

Press <Enter>

Sync Transfer Rate (MB/Sec)

320

Packetized

Yes

QAS

Yes

Initiate Wide Negotiation

Yes (Enabled)

Enable Disconnection

Yes (Enabled)

Send Start Unit Command****

Yes

BIOS Multiple LUN Support

No

Include in BIOS Scan

Yes

Advanced Configuration

Press <Enter>

Reset SCSI Bus at IC Initialization

Enabled

Display <Ctrl><A> Message During BIOS Initialization

Enabled

Extended Int 13 Translation for DOS Drives >1GByte

Enabled

POST Display Mode

Verbose

SCSI-Controller Int 13 Support

Enabled

Domain Validation****

Enabled

Support Removable Disks under Int 13 as Fixed Disks****

Disabled

BIOS Support for Bootable CD-ROM****

Enabled

*Die Einstellung ist nur dann wirksam, wenn Multiple LUN Support eingeschaltet (Enabled) ist.

****Die Einstellung ist nur dann wirksam, wenn der Int 13 Support des SCSI-Controllers eingeschaltet (Enabled) ist.

A26361-D1411-Z120-3-7419

Deutsch - 15

Page 23