FBR211 SERIES
nSPECIFICATIONS
| 
 | 
 | Item | 
 | Standard (A or B type) | 
 | 
 | High sensitive (C or E type) | ||
| Contact | Arrangement | 
 | 1 form C (SPDT) | 
 | 
 | 
 | |||
| 
 | 
 | Material | 
 | ||||||
| 
 | 
 | Resistance (initial) | Maximum 100 mΩ (at 0.1 A 6 VDC) | 
 | |||||
| 
 | 
 | Rating (resistive) | 0.5 A 120 VAC or 1 A 28 VDC | 
 | 
 | 
 | |||
| 
 | 
 | Maximum Carrying Current | 2 A | 
 | 
 | 
 | |||
| 
 | 
 | Maximum Switching Power | 60 VA or 28 W | 
 | 
 | 
 | |||
| 
 | 
 | Max. Switching Voltage*1 | 220 VAC or 150 VDC | 
 | 
 | 
 | |||
| 
 | 
 | Maximum Switching Current | 1.25 A (AC) or 2 A (DC) | 
 | 
 | 
 | |||
| 
 | 
 | Minimum Switching load*2 | Plastic sealed 1 mA, 1V | 
 | 
 | 
 | |||
| 
 | 
 | (reference) | 
 | Flux free 1 mA, 5V | 
 | 
 | 
 | ||
| Coil | Nominal Power (at 20°C) | Approximately 450 mW | 
 | 
 | Approximately 200 mW | ||||
| 
 | 
 | Operate Power (at 20°C) | Approximately 315 mW maximum | 
 | 
 | Approximately 140 mW maximum | |||
| 
 | 
 | Operating Temperature | 
 | 
 | |||||
| 
 | 
 | Operating Humidity | 45 to 85%RH | 
 | 
 | 
 | |||
| Time Value | Operate (at nominal voltage) | Maximum 5 ms | 
 | 
 | 
 | ||||
| 
 | 
 | Release (at nominal voltage) | Maximum 5 ms | 
 | 
 | 
 | |||
| Life | Mechanical | 
 | 5 × 106 operations minimum | 
 | 
 | 
 | |||
| 
 | 
 | Electrical | 
 | 3 × 105 operations minimum (at | 1 A/ | 28 VDC resistive load) | |||
| 
 | 
 | (Refer to the REFERENCE DATA) | 1 × 105 operations minimum (at | 2 A/ | 12 VDC resistive load) | ||||
| 
 | 
 | 
 | 
 | 
 | 
 | 1 × 105 operations minimum (at 0.5 A/120 VDC resistive load) | |||
| Other | Vibration Resistance | 10 to 55 Hz (double amplitude of 1.5 mm) | |||||||
| 
 | 
 | Shock | 
 | Misoperation | 100 m/s2 (11±1 ms) | 
 | 
 | 60 m/s2 (11±1 ms) | |
| 
 | 
 | Resistance | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
| 
 | 
 | 
 | Endurance | 1,000 m/s2 (11±1 ms) | 
 | 
 | 
 | ||
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | ||
| 
 | 
 | Weight | 
 | Approximately 4 g | 
 | 
 | 
 | ||
| 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
| *1 | If the switching voltage exceeds the rated contact voltage, reduce the current. The current values vary according to the type | ||||||||
| 
 | of load. | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
 | 
| *2 | Values when switching a resistive load at normal room temperature and humidity and in a clean environment. The minimum | ||||||||
| 
 | switching load varies with the switching frequency and operation environment. | 
 | 
 | 
 | |||||
nINSULATION
| Item | Standard (A or B) | High sensitive (C or E) | |
| Isolation (initial) | Minimum 100 MΩ (at 500VDC) | 
 | |
| Dielectric | 
 | 500VAC 1 min. (standard) | 
 | 
| Strength | 
 | 1,500VAC 1 min. (high isolation coil and contact) | |
nSAFETY STANDARDS
| Type | Compliance | Contact rating | 
| UL | UL 110 | Flammability: UL  | 
| 
 | E63615 | 0.5A, 120VAC (resistive) | 
| 
 | 
 | 1A, 28VDC (resistive) | 
| CSA | C22.2 No. 14 | |
| 
 | LR 40304, LR 46016 | 
 | 