OPTIONAL POSITIONING OF THERMOSTAT SENSING BULB Continued
4.The mounting clip must be a minimum of 3" from bottom of fireplace to prevent crimping of capil- lary. Once you have decided on a location, clean the area thoroughly. Remove the paper backing from the adhesive on back of mounting clip. Press the clip into the new location so that the thermostat sensing bulb will be positioned vertically with the capillary at the bottom (see Figure 37). Slide the thermostat sensing bulb into the clip.
IMPORTANT: Do not crimp capillary.
Thermostat
Sensing Bulb
Adhesive- backed
Do Not Crimp Mounting Clip Capillary
Capillary
Figure 37 - Positioning the Thermostat Sensing Bulb in the Vertical Position with the Capillary at the Bottom
| SPECIFICATIONS |
| Echo Valley Oak Log |
| Variable |
Btu (Variable) | 16,000/31,500 |
Type Gas | Propane/LP - Natural |
Ignition | Piezo |
Manifold Pressure | 8.0" W.C. - 3.5" W.C. |
Inlet Gas Pressure (in. of water) |
|
Maximum | 14" - 10.5" |
Minimum* | 11" - 5" |
Shipping Weight | 38 lbs. |
* For purpose of input adjustment |
|
| Meadowbrook Oak Log |
| |
Btu (Variable) | 26,000/39,000 |
Type Gas | Propane/LP - Natural |
Ignition | Piezo |
Manifold Pressure | 8.0" W.C. - 3.5" W.C. |
Inlet Gas Pressure (in. of water) |
|
Maximum | 14" - 10.5" |
Minimum* | 11" - 5" |
Shipping Weight | 28 lbs. |
* For purpose of input adjustment |
|