Desa CDL3924PT Make sure equipment shutoff valve is fully open, Control Knob and Ignitor, Pilot

Models: LSL3124P CDL3924PT CDL3924NT

1 32
Download 32 pages 9.88 Kb
Page 19
Image 19
2.Make sure equipment shutoff valve is fully open.

OPERATING HEATER

Continued

LIGHTING

INSTRUCTIONS

3.Turn control knob clockwise  to the OFF position. WARNING:

If fireplace has glass doors, never operate this heater with glass doors closed. If you op- erate heater with doors closed, heat buildup inside fireplace will cause glass to burst. Make sure there are no obstructions across opening of fireplace.

You must operate this heater withafireplacescreeninplace. Make sure fireplace screen is closed before running heater.

NOTICE: During initial operation of new heater, burning logs will give off a paper-burning smell. Orange flame will also be pres- ent. Open damper or window to vent smell. This will only last a few hours.

Note: Home owners generally prefer to op- erate their heater with the chimney damper closed. This will put all the heat into the room. However, there may be times you will desire the full flames of the HI heat setting but will find the heat output excessive. You can open the chimney damper (if you have one) fully or partially to release some of the heat.

Figure 25 - Control Knob and Ignitor WARNING: Damper handle will be hot if heater has been running.

1.STOP! Read the safety information in column 2, page 18.

2.Make sure equipment shutoff valve is fully open.

3.Turn control knob clockwise Button Location to the OFF position.

4.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety information in column 2, page 18. If you donʼt smell gas, go to the next step.

5.Turn control knob counterclockwise Figure 26 - Pilot to the PILOT position. Press in control knob for five (5) seconds (see Figure 25).

Note: You may be running this heater for the first time after hooking up to gas sup- ply. If so, the control knob may need to be pressed in for 30 seconds or more. This will allow air to bleed from the gas system.

If control knob does not pop out when released, contact a qualified service person or gas supplier for repairs.

6.With control knob pressed in, press and release ignitor button. This will light pilot. The pilot is attached to the front burner. If needed, keep pressing ignitor button until pilot lights.

Note: If pilot does not stay lit, contact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Lighting Procedure, page 20.

7.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.

Note: If pilot goes out, repeat steps 3 through 7. This heater has a safety interlock system. Wait one (1) minute for system to reset before lighting pilot again.

8.Turn control knob counterclockwise Manual background to desired heating level. The burners should light. Set control knob to any heat level between HI and LO.

Manual background CAUTION: Do not try to ad- just heating levels by using the equipment shutoff valve.

Ignitor

Button

Control Knob

Figure 25 - Control Knob and Ignitor

Button Location

Ignitor Electrode

Pilot Burner

Thermocouple

 

Figure 26 - Pilot

111347-01E

www.desatech.com

19

Page 19
Image 19
Desa CDL3924PT Make sure equipment shutoff valve is fully open, Turn control knob clockwise to the OFF position, Pilot