For Masonry and Factory-Built Metal Fireplace

OPTIONAL POSITIONING

OF THERMOSTAT

SENSING BULB

For Masonry and Factory-Built Metal Fireplace

If your log set cycles to pilot, but the room tem- perature drops to a lower than ideal comfort level before the log set comes back on, you may want to reposition the thermostat sensing bulb.

The thermostat sensing bulb is located near the gas valve assembly on the mounting bracket. This location allows the thermostat to keep the room temperature at an ideal comfort level for most fireplace applications. For positioning the thermo- stat sensing bulb elsewhere, an adhesive-backed mounting clip is available (see Figure 31).

Tools needed: 1/4" hex driver or socket

1.Remove logs. Locate the gas valve assembly and thermostat sensing bulb (see Figure 32).

2.With 1/4" hex driver or socket, loosen the thermostat screw. Carefully slide the thermostat sensing bulb out of the retaining clamp (see Figure 33).

Note: Do not remove the screw. Make sure you tighten the screw after removing the thermostat sensing bulb.

IMPORTANT: Do not force or bend the thermostat sensing bulb or capillary.

3.The thermostat sensing bulb may be located to the lower right front side of fireplace. Determine location of sensing bulb, but do not mount sensing bulb until step 5. If you have a masonry fireplace, see Figure 34 for location. If you have a factory-built metal fireplace, see Figure 35 for location. If your fireplace has glass doors, position sensing bulb directly behind door gap on right bottom side (see Figure 36).

Figure 31- Adhesive-backed Mounting Clip

Thermostat

Sensing Bulb

Gas Valve Figure 31- Adhesive-backed Mounting ClipFigure 32 - Location of Gas ValveAssembly and Thermostat Sensing Bulb

Assembly

Figure 32 - Location of Gas Valve

Assembly and Thermostat Sensing Bulb

 

Capillary

 

Thermostat

 

Sensing Bulb

Retaining

Thermostat

Screw

Clamp

 

Figure 33 - Removing Thermostat

Sensing Bulb

Thermostat

Sensing

Bulb

 

Adhesive-

Backed

Mounting Clip

Figure 34 - Locating

Figure 35 - Locating

Thermostat

Thermostat Sensing

Sensing Bulb on

Bulb on Factory-

Masonry Fireplace

built Metal Fireplace

Thermostat

 

Sensing Bulb

 

Adhesive-

 

backed

 

Mounting

 

Clip

Glass

 

Doors

Figure 36 - Installing Thermostat Sensing

Bulb behind Glass Doors

111347-01E

www.desatech.com

25

Page 25
Image 25