INSTALLING LOGS

INSTALLATION

Continued

PRESSURE TESTING HEATER GAS CONNECTIONS

1.Open equipment shutoff valve (see Figure 15, page 14).

2.Open main gas valve located on or near gas meter for natural gas or open propane/LP supply tank valve.

INSTALLING LOGS

With the heater set to HI, check WARNING: Failure to position thepartsinaccordancewiththese diagrams or failure to use only parts specifically approved with this heater may result in property damage or personal injury.

3.

Make sure control knob of heater is in the OFF

 

CAUTION: After installation

 

position.

 

 

 

 

 

 

and periodically thereafter,

4.

Check all joints from equipment shutoff valve

check to ensure that no flame

 

to control valve (see Figures 16 and 17). Apply

 

comes in contact with any log.

 

noncorrosive leak detection fluid to all joints.

 

With the heater set to HI, check

 

Bubbles forming show a leak.

 

5. Correct all leaks at once.

 

to see if flames contact any log. If

6. Light heater (see Operating Heater, page 16)

so, reposition logs according to

 

depending on your model). Check all other

the log installation instructions

 

internal joints for leaks.

 

in this manual. Flames contact-

7. Turn off heater (see To Turn Off Gas to Ap-

ing logs will create soot.

 

pliance, page 18 or 20, depending on your

 

 

 

model).

 

 

It is very important to install the logs exactly as

 

 

Equipment

 

instructed. Do not modify logs. Only use logs

 

Gas Control

 

supplied with heater.

 

Shutoff Valve

Propane/LP

 

Valve Location

Supply Tank

Variable Manually-Controlled Models

 

 

 

 

(LSL)

 

 

 

 

1.

Place rear log onto rear brackets making sure

 

 

 

 

 

brackets fit into recess on bottom of log (see

 

 

 

 

 

Figure 18).

 

 

 

 

2.

Place left front log on grate fingers as shown

 

 

 

 

 

in Figure 19, page 16. Place right front log on

 

 

 

 

 

grate fingers and on left front log (see Figure

 

 

 

 

 

19, page 16).

Figure 16 - Checking Gas Joints

(Propane/LP only)

Gas Control

Equipment

Valve Location

Shutoff Valve

 

 

Gas Meter

Figure 17 - Checking Gas Joints (Natural

Gas Only)

3.Slide control cover log into position between two front logs assuring the cover log seats into cutout section (see Figure 20, page 16).

Rear Log

Figure 18 - Rear Log Placement (Variable Manually-Controlled Models)

111347-01E

www.desatech.com