INSTALLATION
Continued
PRESSURE TESTING HEATER GAS CONNECTIONS
1.Open equipment shutoff valve (see Figure 15, page 14).
2.Open main gas valve located on or near gas meter for natural gas or open propane/LP supply tank valve.
INSTALLING LOGS
WARNING: Failure to position thepartsinaccordancewiththese diagrams or failure to use only parts specifically approved with this heater may result in property damage or personal injury.
3. | Make sure control knob of heater is in the OFF |
| CAUTION: After installation | |||
| position. |
|
|
| ||
|
|
| and periodically thereafter, | |||
4. | Check all joints from equipment shutoff valve | |||||
check to ensure that no flame | ||||||
| to control valve (see Figures 16 and 17). Apply | |||||
| comes in contact with any log. | |||||
| noncorrosive leak detection fluid to all joints. | |||||
| With the heater set to HI, check | |||||
| Bubbles forming show a leak. |
| ||||
5. Correct all leaks at once. |
| to see if flames contact any log. If | ||||
6. Light heater (see Operating Heater, page 16) | so, reposition logs according to | |||||
| depending on your model). Check all other | the log installation instructions | ||||
| internal joints for leaks. |
| in this manual. Flames contact- | |||
7. Turn off heater (see To Turn Off Gas to Ap- | ing logs will create soot. | |||||
| pliance, page 18 or 20, depending on your |
|
| |||
| model). |
|
| It is very important to install the logs exactly as | ||
|
| Equipment |
| instructed. Do not modify logs. Only use logs | ||
| Gas Control |
| supplied with heater. | |||
| Shutoff Valve | Propane/LP | ||||
| Valve Location | Supply Tank | Variable | |||
|
|
|
| (LSL) | ||
|
|
|
| 1. | Place rear log onto rear brackets making sure | |
|
|
|
|
| brackets fit into recess on bottom of log (see | |
|
|
|
|
| Figure 18). | |
|
|
|
| 2. | Place left front log on grate fingers as shown | |
|
|
|
|
| in Figure 19, page 16. Place right front log on | |
|
|
|
|
| grate fingers and on left front log (see Figure | |
|
|
|
|
| 19, page 16). |
Figure 16 - Checking Gas Joints
(Propane/LP only)
Gas Control | Equipment | |
Valve Location | ||
Shutoff Valve | ||
| ||
| Gas Meter |
Figure 17 - Checking Gas Joints (Natural
Gas Only)
3.Slide control cover log into position between two front logs assuring the cover log seats into cutout section (see Figure 20, page 16).
Rear Log
Figure 18 - Rear Log Placement (Variable
www.desatech.com | 15 |