Table 6.1 Check items (continued)

Problem

Possible cause

Response

 

 

 

The check

The carrier fixing bracket

Remove the carrier fixing bracket as

indicator is on.

was not removed.

explained in Section 3.2, “Removing the

 

 

Carrier Fixing Bracket.”

 

 

 

 

——————————

Turn the power off then on again. If the

 

 

check indicator turns on again, contact the

 

 

sales person in charge or a Fujitsu service

 

 

representative.*

 

 

 

“Please clean

The pick roller is dirty.

When the power is turned off, the mes-

Pick-roller” is

 

sage is cleared.

displayed on the

 

Even if the message is displayed, the read

operator panel

 

operation can be continued. Clean the

during the read

 

pick roller after the read operation.

operation in the

 

(See Section 5.3.2.)

ADF.

 

 

The unallowable document

If a document not meeting the scanner

Or check

was read in the automatic

specifications is read in the automatic

indicator blinks

document feeder.

document feeder, the document is not fed

at four seconds

(See Section 4.3.)

smoothly and an error message may be

period.

 

displayed.

 

 

 

 

Read the document in the flat bed station.

 

 

 

Paper double feed

Pad is dirty.

Clean the Pad. (See Section 5.3.2)

 

 

 

 

Pad is worn out.

Replace the pad. (See Section 5.4.2)

 

 

 

Miss pick

Pick roller is dirty.

Clean the Pick roller. (See Section 5.3.2.)

 

 

 

 

Pick roller is worn out.

Replace the Pick roller.

 

 

(See Section 5.4.3)

 

 

 

Paper jam

Some foreign particles are in

Clean the ADF (See Section 5.3.2) or

 

ADF.

remove any foreign particles.

 

 

 

*Please chack the test mode in appendix B, if possible, before calling the service representa- tive and inform status of the indicators.