6-43
Function key
This function allocates setup functions to
F1
,
F2
, and
F3
buttons. You can allocate
up to three setup functions.
NOTE
You cannot use this function when the setup mode is brought by pressing
MENU
in the Ready
status.
You cannot allocate the following functions: Interface, IPC-3 mode, TP_IF Baud Rate, RS232C
Baud Rate, SCSI ID, Product ID, Setup Mode Lock, and Function Key itself.
1. In <<SETUP MODE>> initial screen, press
ENTER
.
The <<SETUP MODE>> menu screen
(Settings or Paper Length Check) appears.
NOTE
The “Settings” screen does not appear and
the “Paper Length Check” screen first ap-
pears when your scanner is not controlled
through the video or TP interface.
<<SETUP MODE>>
<<SETUP MODE>>
Settings
<<SETUP MODE>>
Paper Length Check
The
F1
,
F2
,or
F3
button can be used as a shortcut key which enables you to access
the allocated setup function just by pressing the button whenever the scanner is in the Ready state.
This function is valid even in the setup mode lock state (refer to the next function). However, the
F1
,
F2
, and
F3
buttons are invalid in setup, browse, and test modes.
The following is an example of operation when you allocate START and EJECT keys to the
F1
and
F2
buttons respectively.
Remarks
START:starts the operation stopped by EJECT and
sends data to the host computer.
EJECT:stops operation and ejects the paper in the
transport unit.
Allocatable setup functions and other special functions
Setup functions noted above
START key
EJECT key
(Default: Undefined)