Installation Requirements
(6)Service clearance area
The service clearance area, or the sides which must allow access to the HDDs for installation or maintenance, is shown in Figure 4.6.
[Surface X]
• Holes for mounting screw
(Both side)
[Surface Y]
•Interface connection
[Surface Z]
•Holes for mounting screw
Figure 4.6 Service clearance area
(7)External magnetic field
The drive should not be installed near the ferromagnetic body like a speaker to avoid the influence of the external magnetic field.
(8)Leak magnetic flux
The HDDs use a high performance magnet to achieve a high speed seek. Therefore, a leak magnetic flux at surface of the HDDs are large. Mount the HDDs so that the leak magnetic flux does not affect to near equipment.