Installation Requirements

4-6 C141-E237

(6) Service clearance area

The service clearance area, or the sides which must allow access to the HDDs for installation or

maintenance, is shown in Figure 4.6.

[Surface Y]
Interface connection
[Surface Z]
Holes for mounting screw
[Surface X]
Holes for mounting screw
(Both side)
Figure 4.6 Service clearance area
(7) External magnetic field
The drive should not be installed near the ferromagnetic body like a speaker to avoid the influence of
the external magnetic field.
(8) Leak magnetic flux
The HDDs use a high performance magnet to achieve a high speed seek. Therefore, a leak magnetic
flux at surface of the HDDs are large. Mount the HDDs so that the leak magnetic flux does not affect
to near equipment.