ELECTRICAL CHARACTERISTICS
(VCC = 2.4 to 3.6 V, Ta = –40 to +85°C)
*1 : Conditions; fosc = 12 MHz, Ta = +25°C, in locking state.
*2 : VCC = VP = 3.0 V, fosc = 12.8 MHz, Ta = +25°C, in power saving mode
Parameter Symbol Condition Value Unit
Min Typ Max
Power supply current*1ICC*1 fin = 2500 MHz, VCC = VP = 2.7 V
(VCC = VP = 3.0 V) 3.5
(4.0) –mA
Power saving current IPS ZC = “H” or open 0.1*2 10 µA
Operating frequency fin fIN 700 2500 MHz
OSCIN OSCIN –340MHz
Input sensitivity fin*3 Pfin 50system
(Refer to the measurement
circuit.) –15 +2 dBm
OSCIN*3 VOSC –0.5VCC Vp-p
“H” level input voltage Data,
Clock,
LE, PS,
ZC
VIH –VCC × 0.7
V
“L” level input voltage VIL ––VCC × 0.3
“H” level input current Data,
Clock,
LE, PS
IIH*4 ––1.0+1.0
µA
“L” level input current IIL*4 ––1.0+1.0
“H” level input current OSCIN IIH 0 +100 µA
“L” level input current IIL*4 ––1000
“H” level input current ZC IIH*4 ––1.0+1.0
µA
“L” level input current IIL*4 Pull up input –100 0
“L” level output voltage φ
φφ
φPV
OL Open drain output 0.4 V
“H” level output voltage φ
φφ
φR,
LD/fout
VOH VCC = VP = 3.0 V, IOH = –1 mA VCC – 0.4 V
“L” level output voltage VOL VCC = VP = 3.0 V, IOL = 1 mA 0.4
“H” level output voltage Do VDOH VCC = VP = 3.0 V, IDOH = –0.5 mA VP – 0.4 V
“L” level output voltage VDOL VCC = VP = 3.0 V, IDOL = 0.5 mA 0.4
High impedance cutoff
current Do IOFF VCC = VP = 3.0 V,
VOFF = 0.5 V to VP – 0.5 V ––2.5nA
“L” level output current φ
φφ
φPI
OL Open drain output 1.0 mA
“H” level output current φ
φφ
φR,
LD/fout
IOH ––1.0
mA
“L” level output current IOL –1.0
“H” level output current
Do
IDOH*4 VCC = 3 V,
VP = 3 V,
VDO = VP/2
Ta = +25°C
CS bit = “H” –6.0
mA
CS bit = “L” –1.5
“L” level output current IDOL CS bit = “H” 6.0
CS bit = “L” 1.5
Charge pump current
rate
IDOL/IDOH IDOMT*5 VDO = VP/2 –3–%
vs VDO IDOVD*6 0.5 V VDO VP – 0.5 V 10 %
vs Ta IDOTA*7 – 40°C Ta +85°C–10%