(Ta = +25 °C, VCC = 19 V, VCC (O) = 19 V, VREF = 0 mA)

Parameter

Sym-

Pin

Conditions

 

Value

 

Unit

 

 

 

bol

No.

Min

Typ

Max

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

VTH1

16

FB3 = 2 V, Ta = +25 °C

4.183

4.200

4.225

V

 

Threshold voltage

 

 

 

 

 

 

 

 

VTH2

16

FB3 = 2 V,

4.169

4.200

4.231

V

 

 

Ta = −10 °C to +85 °C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Input current

IINE3

16

INE3 = 0 V

100

30

nA

 

 

 

 

 

 

 

 

 

 

Voltage gain

AV

15

DC

100*

dB

 

 

 

 

 

 

 

 

 

 

Frequency

BW

15

AV = 0 dB

2*

MHz

5-2.

bandwidth

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Error amplifier

Output voltage

VFBH

15

4.7

4.9

V

block

 

 

 

 

 

 

 

VFBL

15

20

200

mV

 

[Error Amp3]

 

 

 

 

 

 

 

 

 

Output source

ISOURCE

15

FB3 = 2 V

2

1

mA

 

 

current

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Output sink current

ISINK

15

FB3 = 2 V

150

300

A

 

 

 

 

 

 

 

 

 

 

OUTD terminal

ILEAK

11

OUTD = 17 V

0

1

A

 

output leak current

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OUTD terminal

RON

11

OUTD = 1 mA

35

50

Ω

 

output ON resistor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1,

+INC1 = +INC2 = −INC1

 

 

 

 

 

Input offset voltage

VIO

12,

3

+3

mV

 

13,

= −INC2 = 3 V to VCC

 

 

 

 

 

 

 

 

 

 

24

 

 

 

 

 

6.

 

 

 

 

 

 

 

 

 

 

13,

+INC1 = +INC2 =

 

 

 

 

Current detec-

 

I+INCH

3 V to VCC,

20

30

A

 

24

tion amplifier

 

 

ΔVIN = −100 mV

 

 

 

 

 

 

 

 

 

 

 

block

 

 

 

 

 

 

 

 

 

 

 

+INC1 = +INC2 =

 

 

 

 

[Current

 

 

 

 

 

A

 

IINCH

1, 12

3 V to VCC,

0.1

0.2

Amp1, Current

Input current

 

 

ΔVin = −100 mV

 

 

 

 

Amp2]

 

 

 

 

 

 

 

 

 

 

I+INCL

13,

+INC1 = +INC2 = 0 V,

180

120

A

 

 

24

ΔVin = −100 mV

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IINCL

1, 12

+INC1 = +INC2 = 0 V,

195

130

A

 

 

ΔVin = −100 mV

 

 

 

 

 

 

 

 

 

* : Standard design value