MB39A105

PC =

ID 2 RDS (ON) Duty

=

0.94 2 0.16

92.4

9

 

 

 

 

 

=:

0.104 W

 

 

PS (ON)

=

VD (Max) ID tr fOSC

 

 

6

 

 

=9 0.94 18 109 500 103

6

=: 0.013 W

PS (OFF) =

VD (Max) ID (Max) tf fOSC

6

 

=9 1.20 8 109 500 103

6

=: 0.007 W

PT = PC + PS (ON) + PS (OFF)

=: 0.104 + 0.013 + 0.007

=: 0.124 W

The above power dissipation figures for the MCH3405 is satisfied with ample margin at 0.8 W.

• Inductors

In selecting inductors, it is of course essential not to apply more current than the rated capacity of the inductor, but also to note that the lower limit for ripple current is a critical point that if reached will cause discontinuous operation and a considerable drop in efficiency. This can be prevented by choosing a higher inductance value, which will enable continuous operation under light loads. Note that if the inductance value is too high, however, direct current resistance (DCR) is increased and this will also reduce efficiency. The inductance must be set at the point where efficiency is greatest.

Note also that the DC superimposition characteristics become worse as the load current value approaches the rated current value of the inductor, so that the inductance value is reduced and ripple current increases, causing loss of efficiency. The selection of rated current value and inductance value will vary depending on where the point of peak efficiency lies with respect to load current.

Inductance values are determined by the following formulas.

Inductance value : L

L

VIN2

 

ton

 

 

2IOVO

20

Page 20
Image 20
Fujitsu MB39A105 manual 2I OV O