5.3 Host Commands
C141-E192-01EN 5-25
If an error occurs during multiple sector write operation, the write operation is
terminated at the sector where the error occurred. Command block registers
contain the cylinder, the head, the sector addresses (in the CHS mode) or the
logical block address (in the LBA mode) of the sector where the error occurred.
At command issuance (I/O registers setting contents)
1F7H(CM)0011000R
1F6H(DH) x L x D V Start head No. / LBA
[MSB]
1F5H(CH)
1F4H(CL)
1F3H(SN)
1F2H(SC)
1F1H(FR)
Start cylinder No. [MSB] / LBA
Start cylinder No. [LSB] / LBA
Start sector No. / LBA [LSB]
Transfer sector count
xx
At command completion (I/O registers contents to be read)
1F7H(ST) Status information
1F6H(DH) x L x DV End head No. / LBA [MSB]
1F5H(CH)
1F4H(CL)
1F3H(SN)
1F2H(SC)
1F1H(ER)
End cylinder No. [MSB] / LBA
End cylinder No. [LSB] / LBA
End sector No. / LBA [LSB]
00 (*1)
Error information
*1 If the command is terminated due to an error, the remaining number of
sectors of which data was not transferred is set in this register.