OPERATING TIPS

Temperature and Humidity Range

 

Cooling Mode

Dry Mode

Outdoor temperature

About 14 to 115 °F

About 14 to 115 °F

 

 

 

Indoor temperature

About 64 to 90 °F

About 64 to 90 °F

 

 

 

If the air conditioner is used under higher temperature conditioner than those listed, the built-in protection circuit may op- erate to prevent internal circuit damage. Also, during Cooling and Dry modes, if the unit is used under conditions of lower temperature than those listed above, the heat-exchanger may freeze, leading to water leakage and other damage.

Do not use this unit for any purposes other than the Cooling, Dehumidifying, and air-circulation of rooms in ordinary dwell- ings.

If the unit is used for long periods under high-humidity conditions, condensation may form on the surface of the indoor unit, and drip onto the floor or other objects underneath. (About 80% or more).

If the outdoor temperature is lower than the temperature scope in the list above, in order to keep safety operation of device, the outdoor unit may stop operation for certain period of time.

SPECIFICATION

TYPE

COOLING MODEL

 

 

MODEL

INDOOR UNIT

ASU30CLX1

ASU36CLX1

 

OUTDOOR UNIT

AOU30CLX1

AOU36CLX1

POWER

 

208/230 V 60 Hz

COOLING

 

 

 

 

CAPACITY

30,700 Btu/h

33,000 Btu/h

 

INPUT POWER

3.24 kW

3.88 kW

 

CURRENT

14.2 A

17.0 A