• FEATURES setup screen has the following 5 options.

Adjustment

: Can make a fine adjustment of pictures such as Dot Clock, Clamp Position.

Function

: Allows setting of 24-frame mode and Jaggies filter. (See P. E-40.)

On Screen Menu : Can make a display setting such as OSD, Language. (See P. E-40E-41.)

Input Terminal

: Can make an input terminal setting such as Video Input. (See P. E-41E-42.)

Others

: Can make other settings. (See P. E-42E-44.)

ADJUSTMENT

Dot Clock, Clock Phase, Clamp Position, and Auto Calibration are adjusted as shown in the following chart.

Select the item with , and then adjust with . Finally, press to implement the adjustments.

Adjustment Item

Contents of Adjustments

 

Operation

Adjustment Range/Remarks

 

 

 

 

 

Dot Clock

You may find the vertically-striped pattern in

Use

to adjust to minimize

–60 to +60

(RGB2, RGB3)

pictures, depending on the clock frequency of your

vertically-striped pattern in pictures.

 

 

PC’s processor.

 

 

 

 

If you experience blurring, you can obtain a clearer

 

 

 

 

picture by adjusting the “Dot Clock”.

 

 

 

 

 

 

 

 

Clock Phase

Pictures and the outline of letters may blur or

Use

to adjust to minimize

Auto/Manual

(RGB2, RGB3)

flicker as the clock phase of your PC may be

pictures blur.

Manual: 1 to 32

 

different. In this case, adjust the clock phase

 

 

 

 

manually. Normally, the automatic setting ensures

 

 

 

 

the optimal value.

 

 

 

 

 

 

 

 

Clamp Position

Normally, the automatic setting ensures the optimal

Use

to adjust pictures

–8 to +8

(RGB2, RGB3,

value. Adjusts the extremely dark or bright pictures.

optimally.

 

Comp.video)

 

 

 

 

 

 

 

 

Auto Calibration

Adjusts the dynamic range of images to the

Display the Auto Calibration screen

Execute/Cancel

(RGB2, RGB3)

optimum. Performed while a white screen signal is

and select Execute, and then use

 

 

received.

 

to select the item.

 

 

 

 

 

 

* On-screen information disappears if you do not take any action for about 60 seconds.

English

E-39