Setup and Guided Tour

Operation of the MS Series is basic and straightforward. The controls and operation are mostly intuitive and self-explanatory, but are discussed here in detail to allow any user to operate it successfully.

Install the unit in its rack and connect the external power supply to the 5-pin DIN DC POWER INPUT connector on the rear panel. Connect an appropriate line cord to the power input on the supply box, and to the AC mains. The power supply accepts any input voltage from 100 to 240 VAC.

Analog Audio Monitoring

Connect active analog audio sources to each of the balanced XLR inputs on the rear panel. (Please refer to Figures 1-4 on page 9 for the locations of controls and indicators.) When the unit is powered up and audio above -28 dBu is present, the SIG (Signal) LEDs next to each input and output connector should flash. If you have a unit with digital capability, set the A/D SELECT button to

ANALOG.

Next, vary the VOLUME and BALANCE sliders (BALANCE is present in non-video units only) to confirm that they affect the speakers and headphones identically. The BALANCE slider should move the stereo image from full left to full right. The headphones DO NOT disable the speakers when they are inserted into the HEADPHONE jack. Headphone monitoring is intended to minimize the distracting effects of surrounding ambient sound for the operator. The speakers are still active when the headphones are plugged in to provide audio to others in the immediate area for confidence, while the operator is monitoring the audio specifically. Nevertheless, the speakers can be muted if desired by pressing the SPEAKER MUTE button. An indicator LED lights when the speakers are muted. The SPEAKER MUTE button does not affect the headphones.

With audio input, the Level Meters will vary according to the BALLISTICS selected, either VU or PPM. Note that there is a PK (Peak) LED that will illuminate when the audio level exceeds +4 dBu. The movement of the meters is from -40 dBu to +3 dBu, left to right as is seen in analog metering. The zero reference of the meters may be set to either +4 dBu or +8 dBu with the REF/dBu button. Successive presses of the button will toggle between the two references. An indicator LED glows above the selected reference, which affects all meters on the unit.

NOTE:Choose VU for a slower, time-averaged meter response. Choose PPM for an extremely fast response which displays all peaks.

The brightness of the Level Meters’ LED displays can be varied by the DIMMER control at the very left side of the front panel assembly. This control will vary the brightness from “Full On” to slightly visible. The Level Meters cannot be dimmed completely as this may cause an erroneous reading by operators not aware of the dimmed setting. This adjustment requires a small flat-blade screwdriver and has a travel of 270 degrees of rotation.

When normal, in-phase stereo signals are applied to the MS Series unit, the PHASE indicator will glow green, with an occasional yellow flicker. If one channel is disconnected or reduced to zero, the color will change to steady red. It will also be mainly red for out-of-phase stereo.

NOTE: Out-of phase stereo is not compatible with conversion to mono. The out-of-phase condition should be corrected, or there may be substantial level loss when left and right are summed to mono.

4

Page 4
Image 4
Furman Sound MS2A-1 owner manual Setup and Guided Tour, Analog Audio Monitoring

MS2A-1 specifications

Furman Sound has long been a leader in power management and conditioning solutions, and its MS2A-1 model continues this legacy with advanced features and innovative technologies designed for professionals in audio and video production settings. The MS2A-1 is a robust and reliable power conditioner that ensures optimal performance for your electronic equipment, safeguarding it from inevitable power fluctuations.

One of the main features of the MS2A-1 is its advanced Linear Filtering Technology (LiFT), which utilizes RF filtering to eliminate noise and provide a clean power supply. This technology is critical in reducing audio and video interference, resulting in significantly improved sound quality and image fidelity. As professionals know, consistent power delivery is vital in maintaining the integrity of sensitive equipment, and the MS2A-1 excels in this area.

Another important characteristic of the MS2A-1 is its Rack-Mountable Design. With a standard 1U rack height, this power conditioner can easily fit into any standard 19-inch rack system, allowing for a neat and organized setup in both live and studio environments. The front panel features convenient AC outlets, allowing for easy access to your critical equipment.

In terms of surge protection, the MS2A-1 is equipped with an inbuilt surge suppression system that shields connected devices from voltage spikes and electrical surges. This is an essential feature for any audio professional, as unreliable power sources can lead to equipment damage and costly downtime. With its premium components and proven protection strategies, the MS2A-1 ensures that your gear remains safe and operational.

Additionally, the MS2A-1 provides voltage regulation capabilities, crucial for environments where power supply can vary. This device maintains a consistent voltage level, which is especially beneficial in live performances or locations where fluctuating voltage can adversely affect performance.

Lastly, the MS2A-1 features a compact and lightweight construction, making it easy to transport to gigs or events, while still providing superior protection and performance. By combining advanced technologies with user-friendly design, the Furman Sound MS2A-1 stands out as an essential tool for audio and video professionals who demand the very best in power conditioning. Whether you’re in the studio or on stage, the MS2A-1 delivers reliability and exceptional performance, helping you focus on your creative work without worrying about power concerns.