SERIES II 20 amp Power ConditionerS

SPECIFICATIONS

Current rating:

20 amps (“E” versions 16 amps)

Operating Voltage:

90 to 140 VAC (“E” versions 180 to 280 VAC)

Over Voltage Shutdown:

140 VAC typically (“E” versions 260 VAC typically, “J” ver- sions 125 VAC typically)

Voltmeter Accuracy:

PL-PRO II only: ±2 VAC, calibrated with internal trimpot adjustments

PL-PRO D II & PM-PRO II: ±1.5 VAC,

PM-PRO II Current meter: ±0.5 amp

Spike Protection Modes:

Line to neutral, zero ground leakage

Spike Clamping Voltage:

188 Vpk @ 3,000 amps, (133 VAC RMS) (“E” Version: 376 Vpk (266 VAC RMS)

Response time:

1 nanosecond

Maximum surge current: 6,500 amps

Noise attenuation: 10 dB @ 10 kHz

40 dB @ 100 kHz

100 dB @ 10 MHz

Linear attenuation curve from 0.05 - 100 ohms line imped- ance

Mechanical:

Dimensions: 1.75” H x 19” W x 10.5” D.

Weight: 11 lbs (5 kg).

Construction: Steel chassis, .125” brushed and black anod- ized aluminum front panel; glass epoxy printed circuit boards

Power Consumption: PL-PRO II, 12 watts PL-PRO D II, 12 watts PM-PRO II, 12 watts

Safety Agency Listings:

CE, NRTL-C

Make sure to pick up one of Furman’s goosneck lights - the perfect accesory for your Series II unit.

GN-LED

GN-I