Furuno TR-1 Mounting Considerations, Installation, Radar/Chartplotter MARPA Configuration

Models: TR-1

1 4
Download 4 pages 15.85 Kb
Page 3
Image 3
Mounting Considerations

Mounting Considerations

The Integrator unit is mounted on any flat surface, using two #6 screws provided, through the mounting holes in the case. The unit should be located so its LED is visible to the helmsman during normal boat operation, but not directly in the line of vision due to the brightness of the LED. Although the Integrator is a completely sealed unit it should be mounted in a location that is not subject to immersion or water from wash down.

Installation

Installation of The Integrator consists of mounting the device in a suitable location, connecting wiring for NMEA input and AD10 output signals, and providing a switched 12 volt power supply and ground.

NMEA Out

Red ( + )

Red ( + )

Red ( + )

Switched

{ Black ( - )

Black ( - )

 

Black ( - )

12 V Pwr

Gladiator

 

 

 

 

Source

Compass

 

 

 

 

 

Ball

 

 

 

 

 

 

 

 

Integrator

Connects To

 

 

 

 

Wire Color

 

 

 

 

 

 

 

 

 

Orange AD10 Clock + Furuno Clock + (Yellow)

 

 

 

 

Green Ad 10 Clock - _ Furuno Clock - (Green)

 

 

 

 

Blue AD 10 Data +

Furuno Data + (White)

 

 

 

 

Brown AD 10 Data -

Furuno Data - (Black)

 

Connector

Wire Color

Signal

Connects To

 

Power

 

Red

+ 12 VDC

Switched Power Source

 

 

 

Black

Ground

Engine Ground

 

NMEA 0183

Red

NMEA +

Gladiator NMEA Out + (Red)

 

 

 

Black

NMEA -

Gladiator NMEA Out - (Black)

 

AD10

 

Orange

AD10 Clock +

Furuno Clock + (Yellow)

 

 

 

Green

AD 10 Clock -

Furuno Clock - (Green)

 

 

 

Blue

AD10 Data +

Furuno Data + (White)

 

 

 

Brown

AD 10 Data -

Furuno Data - (Black)

 

Radar/Chartplotter MARPA Configuration

The radar or plotter should be configured for magnetic oriented AD10 data when using the TR-1 Gladiator as the heading data source. As setup procedures are unit specific, please refer to the operator’s manual of your Radar/Charplotter, for proper configuration procedure.