Gardena 1559 manual 2 4, Anti-vandal device, Information about programming

Models: 1559

1 12
Download 12 pages 39.03 Kb
Page 5
Image 5
Anti-vandal device:

GB

Programme contour points of irrigation sector:

A

B

0

2 4 3

1 6 5

Anti-vandal device:

If the nozzle head is turned beyond the sector stops with the sector stops held, the anti-vandal device will be triggered.

As soon as the water supply is opened, the large-area pop-up irrigation will automatically return to the watering sector.

The head of the Large-Area Irrigation can turn around 360° before the original position is reached again.

The watering sector has to be selected before programming. Up to 50 contour points can be programmed with the large- area pop-up irrigation. The more points that are programmed, the more precisely the contour will be described (e.g. with a circular arc P7 – P10).

1.Open the two locks A and raise the cover B.

2.Open water supply.

When using for the first time, the minimum range (2.5 m with a flow pressure of 2 bar at the sprinkler) is selected.

3.Press OK button 4. The green Auto LED 6 lights up.

4.Press Menu button 1. The red Set LED 5 lights up.

5.Turn the nozzle head 0 on the orange ring by hand to the left-hand sector limit (in the example P1) and hold.

6.Use the two buttons “+” button 2 and “-”button 3 to set the range so that it reaches P1.

7.Press OK button 4.

The green Auto LED 6 lights up for 1 second and the first point P1 has been stored.

8.Turn the nozzle head 0 on the orange ring by hand to the next irrigation point (e.g. P2) and hold.

9.Use the two buttons “+” button 2 and “-”button 3 to set the range so that it reaches P2 for example.

10.Press OK button 4.

The green Auto LED 6 lights up for 1 second and the point has been stored.

11.Repeat the process from step 8 to 10 until the right-hand sector limit is reached (in the example P10).

12.Press Menu button 1.

The red Set LED 5 goes out, programming is complete, and the green Auto LED 6 lights up for 1 minute. The Auto LED then flashes every 10 seconds.

13.Release nozzle head 0 and check contour area watered.

14.If the contour is watered correctly, close the water supply.

15.Close cover B and both locks A.

Information about programming:

As soon as the first point is programmed, any existing programme will be deleted. After programming has been completed, no further points can be deleted or added later on. If the contour has not been set as required, reprogramming with more points will have to be carried out. If no button is pressed for 60 seconds during programming, programming will be automatically ended and the contour stored.