Clean nozzles:
A |
GB | D |
B |
Clean protective panel of solar cell:
If the watering pattern is no longer even, the nozzles can be cleaned using the cleaning needle provided.
1. Open both locks A and raise the cover B.
2. | Turn the cleaning needle D | E |
| (e.g. with a coin) anticlockwise |
|
| through 180° 1 and pull out |
|
| carefully 2 (bayonet coupling). |
|
3. | Clean nozzles E with cleaning | D |
| needle D. |
4.Refit cleaning needle D in reverse order.
5.Close cover B and both locks A.
To make sure that the rechargeable battery is always sufficiently charged, the protective panel of the solar cell has to be cleaned if soiled.
No caustic / abrasive cleaning agents or hard objects should be used.
vClean protective panel of solar cell with a damp cloth.
8. Troubleshooting
Fault | Possible cause | Remedy | |
Irrigation width smaller than | Dirt filter soiled. | v Clean dirt filter. | |
on initial |
|
| |
Tap not opened sufficiently. | v Open tap further. | ||
| |||
|
|
| |
| Water pressure too low. | v Increase water pressure / | |
|
| water supply. | |
|
|
|
Rechargeable batteries almost flat (Auto and Set LED flashing) / Protective panel of solar cells soiled.
vEnsure solar cells are exposed to sufficient sunlight / clean protective panel. If the rechargeable battery is almost flat, the range is reduced to the min. level.
| v Press OK button. | |
| is in |
|
| (4 weeks without energy |
|
| supply or operation). |
|
|
|
|
| Irrigation range is programmed | v Reprogramme irrigation |
| incorrectly. | range. |
|
|
|
Watering pattern uneven | Nozzles soiled. | v Clean nozzles. |
|
|
|
| Nozzle head soiled. | v Clean nozzle head. |
|
|
|
| Nozzle head damaged. | v Contact GARDENA Service. |
|
|
|
Auto and Set LED flashing | Rechargeable batteries almost | v Ensure solar cell is exposed |
simultaneously | discharged. | to sufficient sunlight. |
|
|
|