. The minimum operating pressure is 1 bar, the maximum operating pressure is 12 bar.
. Check the filter in the sleeve nut 7 regularly and clean if necessary.
. Avoid tensile strain. Do not pull the hose connected to the Water
Timer Electronic.
. Only use clear fresh water.
9. Anti-Theft Protection (Fig. D)
To protect your Water Timer against theft, the GARDENA
The bracket on the
10. GARDENA Soil Moisture Sensor (Fig. E)
Together with the GARDENA Soil Moisture Sensor (Art. No. 1187) watering is controlled considering the soil moisture.
Assembly
The Soil Moisture Sensor is connected to the connection socket 6 on the back of the control unit (Fig. A).
How it works
If the connected Soil Moisture Sensor indicates there is sufficient moisture then the watering program is either interrupted or not initiated.
Note: Manual watering (function
11. GARDENA Rain Sensor (Fig. F)
Together with the GARDENA Rain Sensor (Art. No. 1189) watering is controlled considering natural precipitation.
Assembly
The Rain Sensor, as an alternative to the Soil Moisture Sensor, can be connected to the connection socket 6 on the back of the control unit (Fig. A).
How it works
If the connected Rain Sensor indicates an appropriate amount of rain, the watering program is interrupted or not initiated.
Note: Manual watering (function
10
12. Faults
Fault | Possible Cause | Remedy | |
|
|
| |
Not able to open the | Battery power too low. | Insert a new | |
Water Timer using |
| alkaline battery. | |
the |
|
| |
Tap turned off. | Turn on tap. | ||
function. | |||
|
| ||
|
|
| |
Watering not | Battery power too low. | Insert a new | |
initiated. |
| alkaline battery. | |
|
|
| |
| Data input / changes | Input data or make | |
| made while the pro- | changes before or | |
| gram was starting or | after the starting times | |
| immediately before. | you have chosen. | |
|
|
| |
| Tap turned off. | Turn on tap. | |
|
|
| |
| Soil Moisture Sensor | If dry, check setting/ | |
| or Rain Sensor indi- | position of the Soil | |
| cate sufficient moisture. | Moisture Sensor or | |
|
| Rain Sensor. | |
|
|
| |
Battery flat after | Not an alkaline | Use an alkaline | |
working for a | battery. | battery. | |
short time. |
|
| |
|
|
|
If you have any problems with your Water Timer Electronic, please contact our Customer Service or return the defective unit together with a short description of the problem directly to one of the GARDENA Service Centres listed on the back of this leaflet.
If covered under warranty, please include a copy of the receipt.
We expressly point out that, in accordance with the product liability law, we are not liable for any damage caused by our units if it is due to improper repair or if parts exchanged are not original GARDENA parts or parts approved by us, and, if the repairs were not carried out by a GARDENA Service Centre or an authorised specialist. The same applies to spare parts and accessories.
11