11. Recommended Accessories

The pump switches on and off because of a leak. If the

Pump and suction hose

are not filled up with the

G

The pump switches on and

off because of a leak. If the

11. Recommended Accessories

G

pump switches on and off more than 7 times within 2 minutes, the

control unit issues a warning via flashing LEDs and the motor switches itself off. Note: The pump can only be restarted by “re-plugging”.

Finding Faults

Important! Unplug the pump. Check the pump for possible faults such as:

Faulty or leaking back-flow

preventer at the end of the

suction hose

liquid to be pumped

Backflow valve switch set

to position 2 and was not set

to position 1 once the pump

began pumping

Suction hose end is not sub-

merged into the liquid

Outlet too low

Suction hose or connections

are not water-tight

Suction filter clogged

Air cannot escape on delivery

side since release points are

closed etc.

Delivery pipe or consumer are

not water-tight

pump switches on and off more

than 7 times within 2 minutes,

the control unit issues a warn-

ing via flashing LEDs and the

motor switches itself off.

Clear the fault. Plug in the pump in order to start again operation of the pump.

Shouldn’t the pump start prim- ing, although you have repeat- edly pressed the RESET button, please contact one of our GARDENA Service Centres (addresses you will find on the rear side).

.

.

GARDENA Suction Hoses Kink- and vacuum-resistant, sold by the metre with 19 mm (3/4) or 25 mm (1) diameter without fittings or in fixed length, complete with fittings.

GARDENA Suction Hose Fittings (art. no. 1723/1724)/ Suction Filter with Backflow Preventer (art. no. 1726/ 1727/1728)

To equip suction hoses sold by the metre.

. GARDENA Pump

Preliminary Filter, art. no. 1731 Recommended for pumping sandy liquids.

art. no. 1730, recommended for pumping sandy liquids and higher water quantities.

. GARDENA Bore Hole

Suction Hose, art. no. 1729 For vacuum-resistant connec- tion of the pump to boreholes or pipe networks. Length 0.5 m. With 33.3 mm (G 1) female thread at both ends.

12. Trouble-Shooting

9. Operation Hints

Problem

Probable cause

Remedy

 

 

 

Pump motor runs,

Leaks at suction side.

Eliminate leak.

.

.

.

Don’t use the power cable

.

for carrying the pump or for

 

plugging off. Protect the

 

power cable from heat, oil

.

and sharp edges.

 

Please unplug the pump

 

after operation and before

 

carrying out any mainte-

.

nance works.

 

In order to avoid dry-running

 

of the pump, take care that

 

the end of the suction hose

.

is always submerged into

 

the liquid.

 

The temperature of the liquid to be pumped must not exceed

35 °C.

Sand and other abrasive sub- stances in the liquid cause increased wear and reduce the pump’s output.

The pump is not designed for continuous operation (e.g. industrial application, continu- ous circulating operation). The minimum flow rate is

90 I/h (= 1.5 I/min). Watering accessories with lower rate must not be operated.

. When using the pump for pres- sure intensification, the max. permissible internal pressure of 6 bar (on the delivery side) must not be exceeded.

The to be increased delivery pressure and the pump pres- sure sum up.

Example: pressure at the water tap 1.5 bar, max. pressure of the GARDENA Pressure Tank Unit 4000/4 electronic plus 4.2 bar, total pressure 5.7 bar.

but delivery capacity

Suction filter at the suction hose

To adjust the flow rate of the

is totally or partly sucked free.

suction side to the delivery side,

or pressure suddenly

 

reduce the flow rate at the pump’s

decreases.

 

delivery side G. Observe min.

 

 

flow rate (see section 9).

 

 

 

 

Suction filter or backflow

Clean filter or backflow preventer.

 

preventer clogged.

 

 

 

 

 

Turbine clogged.

Unplug and clean the turbine

 

 

(see point 10).

 

 

 

Pump doesn’t deliver water.

Leaks at suction side.

Eliminate leak.

 

 

 

Pump switches on and off

Dirt has collected on the

1. Remove manometric switch

continuously if liquid is

impeller.

from pump.

drawn at a rate greater than

 

2. Return valve set to position 2.

10. Maintenance, Care, Storage (ill. B/C)

400 l/h.

3. Rinse manometric switch

Attention! Disconnect Athe plug from the mains before carrying out any work on the pump!

A turbine clogged by contamina- tion can be released by using a screwdriver to turn over the turbine axle B (observe the arrow on the casing indicating the direc- tion of rotation). If this is not pos- sible any more, the turbine space can be cleaned by opening the

screws 9 and removing the casing cover 0.

The turbine A can be removed if necessary, by using a screw- driver to hold the turbine axle B in place while loosening the turbine A with a ring spanner at the same time.

When assembling, take care that the parts are re-assembled cor- responding to the sequence of the disassembly.

Before the first frost sets in, the pump should be drained via the water drain screw 1. Store it protected from frost.

To empty the Electronic Mano- metric Switch 5 put the rotary switch C in position 2 and open the water drain screw 1.

Pump doesn’t start or

No power.

Check fuses and electric connec-

suddenly stops during

 

tions.

operation.

 

 

Circuit breaker has cut out the

Disconnect at the mains and clean

 

 

pump because of overloading.

the turbine (refer to “Maintenance,

 

 

Care and Storage”). Observe

 

 

max. liquid temperature (35 °C).

 

 

 

 

Electric failure.

Send the pump to one of our

 

 

GARDENA Service Centres.

 

 

 

 

Electronic Manometric Switch

First disconnect the plug

 

calcified.

A at the mains! Then lower

 

 

the pressure, e. g. by opening

 

 

a consumer.

 

 

Decalcify the Electronic Mano-

 

 

metric Switch. Unplug it, discon-

 

 

nect the pressure hose / pressure

18

19

Page 6
Image 6
Gardena Art.1482 Recommended Accessories, Trouble-Shooting, Operation Hints, Maintenance, Care, Storage ill. B/C