![EU Certificate of Conformity](/images/new-backgrounds/65469/6546913x1.webp)
G
|
| line and fill antiliming agent or a |
|
| mixture of water and vinegar into |
|
| the pump using the delivery outlet |
|
| 6. Afterwards rinse thoroughly. |
|
|
|
Pump constantly cuts in | Leak on the pressure side. | Check the pressure line and |
and out without drawing |
| connected consumers for leaks. |
water. |
| The |
|
| position 1 when localising faults. |
|
| Note: Even the smallest leak |
|
| (loss of a few mls) can cause the |
|
| pressure in the pump to drop. |
|
| The cause of this is often small |
|
| leaks at taps and toilet flushing |
|
| cisterns. |
|
|
|
| There being deposits of dirt in | Loosen the Electronic Mano- |
| in Electronic Manometric Switch. | metric Switch from the pump. |
|
| Turn the |
|
| position 2. |
|
| Clean the |
|
| by flushing in the direction of flow. |
|
|
|
Pump does not cut out. | Rotary switch / | Set the rotary switch to posi- |
| valve is set to position 2. | tion 1. |
|
|
|
| Clean the | |
| Manometric Switch is blocked. | by flushing in the direction of flow. |
|
|
|
| Larger leaks on the pressure side. | Rectify leaks. |
|
|
|
Pump doesn’t start | Outlet end (e.g. water accessory) | Open the outlet end. |
working. | is closed. There is sufficient water |
|
| pressure in the pressure line. |
|
|
|
|
G
EU Certificate of Conformity
The undersigned
GARDENA Kress + Kastner GmbH ·
hereby certifies that, when leaving our factory, the units indicated below are in accordance with the harmonised EU guidelines, EU standards of safety and product specific standards.
This certificate becomes void if the units are modified without our approval.
Description of the units: | Directive 93/68/EC | Year of CE marking: | ||
Pressure Tank Unit | Directive 2000/14/EC | 1996 | ||
Types: | Harmonised |
| ||
4000/4 electronic plus | European standards: | Ulm, 21.02.2002 | ||
4000/5 electronic plus | EN 292 |
| ||
Art. nos.: | EN 292 - 2 |
| ||
EN 60335 |
| |||
1482 / 1484 |
| |||
EN 60335 - 2 - 41 | Thomas Heinl | |||
EU directives: | ||||
Noise level: | Technical Dept. Manager | |||
Machinery Directive 98/37/EC |
| |||
| measured / guaranteed |
| ||
Electromagnetic Compatibility |
|
| ||
1482 | 77 / 78 dB (A) |
| ||
89/336/EC |
| |||
1484 | 79 / 80 dB (A) |
| ||
Low Voltage Directive 73/23/EC |
| |||
|
|
|
If you have any problems with your Pressure Tank Unit, please contact our Service or return the defective unit together with a short description of the problem – in case of guarantee, with a copy of the receipt – postage paid to one of the GARDENA Service Centres listed on the back of this leaflet.
Note : The pump can also be operated without the Electronic Manometric Switch 5 by plug- ging the mains plug for the pump F into the mains socket. If the fault is caused by the Electronic Manometric Switch, then it is sufficient to forward this to the appropriate servicing office.
We expressly point out that,
in accordance with the product liability law, we are not liable for any damage caused by our units if it is due to improper repair or if parts exchanged are not original GARDENA parts or parts approved by us, and if the repairs were not carried out by a GARDENA Service Centre or an authorised electrician. The same applies to spare parts and accessories.
20 | 21 |