5. Cleaning

5. Cleaning

Cleaning the Pressure Sprayer:

6. Trouble-Shooting

Always clean your Pressure Sprayer after spraying.

vFill the Pressure Sprayer with clean water (the water may contain some washing-up liquid if necessary) and empty out the water by spraying it through the spray tube in the same way as when spraying a product.

This cleans the valves, the spray tube and the nozzles.

We recommend that you have your Pressure Sprayer thoroughly inspected (preferably at a GARDENA Service Centre) after using it for 5 years.

GB

Cleaning the filter:

If the spray jet from the Pressure Sprayer is very weak you

 

should clean the filter in the container.

 

Pressure Sprayer Art. No. 867/ 869

 

1.

Unscrew the container cap.

7

2.

Flip up the filter 7 and rinse under running water.

3.

Close the filter 7 and screw the container cap back on.

3

 

 

W

Pressure Sprayer Art. No. 875 / 879 / 880

Remove the filter W from the spray tube 3 and clean it.

Problem

Possible Cause

Remedy

Pump does not build up

Container cap is not airtight.

v Fasten the container cap

pressure.

 

as tight as it will go

 

 

(Art. 867/ 869).

 

 

 

 

Safety valve is loose.

v Tighten the safety valve.

 

 

 

 

Hose connection at the container

v Tighten the hose connec-

 

and hand valve is not tight.

tions at the container and

 

 

hand valve.

 

 

 

 

Continuous lock enabled on

v Take off the permanent lock

 

handle.

at the hand valve.

 

 

 

Pressure Sprayer does not

Nozzle is blocked.

v Clean the nozzle.

spray although there is

 

 

Filter is blocked.

v Clean the filter in the

sufficient pressure or only

 

container (Art. 867/ 869).

sprays with a weak spray jet.

 

 

Clean the filter in the spray

 

 

 

 

tube (Art. 875 / 879 / 880).

 

 

 

It is difficult to open and

Container pressure too high.

v Release the container pres-

close the container.

 

sure completely by means

 

 

of the safety valve.

 

 

Grease the container O-ring

 

 

with acid-free grease

 

 

(Art. 867/869).

 

 

 