Garland E24-48G Unpacking, Leg Installation, Electrical Connections, E24-12H Hot Plate

Models: E24-12H E24-24G E24-36G E24-60G E24-48G E24-72G

1 12
Download 12 pages 63.95 Kb
Page 7
Image 7
INSTALLATION

INSTALLATION

Unpacking

Unpack units carefully and provide the necessary space on counter of back bar.. All units must be installed following the minimum back and side clearances stated on the tag affixed to each individual unit.. To insure proper field wiring size check tag attached to the rear of the unit near knockout..

Leg Installation

1.All units are shipped with N..S..F.. approved legs.. These legs must be installed to provide a minimum clearance of 4” (102mm) between he counter top and bottom of the appliance in order to meet the National Sanitation Foundation requirements..

2.When using the legs described above, raise the front of the appliance and screw the leg into the leg-retaining nut provided at each corner of the appliance, repeat at each rear..

3.The unit may be leveled by adjusting the legs.. Use a spirit level and level the appliance four (4) ways: across the front and back; and down left and right edges..

NOTE: Griddles may not rest evenly on the appliance body if the appliances are not leveled..

Electrical Connections

Before attempting the electrical connection, the rating plate should be checked to ensure that the unit’s electrical characteristics and the supply characteristics agree..

Installation of the wiring must be made in accordance with UL 197 Commercial Electric Cooking Appliance Standards, Local and/or National Electrical Code, and ANSI/NFPA 70- 1990 and include..

1.Switch panel size

2.Overload protection

3.Wire type

4.Wire size

5.Temperature limitations of the wires

6.Method of connection (Cable, Conduit, etc..)

The service line enters though the rear of the unit and is to be connected to the terminal block.. Input voltage and phasing must match the unit’s voltage and phasing..

Visually check all electrical connections..

Energize the electrical connections..

NOTE: Appliances are not internally fused.. They must be connected to a suitable disconnect box in accordance with local code..

E24-12H Hot Plate

Electrical connection to the terminal may be made though the knockout on the main back.. Front access is gained by raising the rear surface element and removing bowl.. The terminal block shield is located toward the back lower left of the unit..

E24 Series Griddles

The electrical connections may be made though the knockout at the rear of the unit to the terminal block located behind the terminal block shield..

Front access is gained by raising and propping the griddle plate.. The terminal block shield is toward the back and left of the appliance.. Remove the shield to expose the terminal block.. Make the necessary connection and replace the shield.. These appliances have no fusing..

Part # 1009080 Rev 5 (01/25/08)

Page

Page 7
Image 7
Garland E24-48G, E24-72G Unpacking, Leg Installation, Electrical Connections, E24-12H Hot Plate, E24 Series Griddles