Garland ECG Installation Procedure, Commissioning, Operating Instructions, All Models, General

Models: ECG

1 12
Download 12 pages 27.99 Kb
Page 5
Image 5
ALL MODELS

ALL MODELS

SIDES

BACK

COMBUSTIBLE WALL

MINIMUM CLEARANCE

mm

ins

152

6

152

6

NON-COMBUSTIBLE WALL

MINIMUM CLEARANCE

mm

ins

152

6

152

6

INSTALLATION PROCEDURE

GENERAL

1.Carefully remove the unit from the crate. All packing material must be removed from the unit. The protective material covering the stainless steel must be removed immediately after the unit is installed.

2.Adequate clearance must be provided for servicing, ventilation and proper operation. The product must be kept clear of combustible material.

CASTERS

1.The front casters on the unit are equipped with brakes to limit movement of the range without relying on the electrical connection to limit appliance movement.

2.A restraint can be attached to the unit near the electrical connection. If the restraint is disconnected, be sure to reconnect it after the range has been returned to its originally installed position.

COMMISSIONING

Ensure all circuit breakers located behind the access door on the control panel are set to the “ON” position.

1.Ensure that all controls are in the “OFF” position and turn on the main electrical supply.

2.Operate each section of the unit in accordance with the operating instructions provided in this manual.

3.Check that the product functions correctly and the voltage supply to the unit does not drop by more than 5% when all sections are operated simultaneously.

When the operation has been checked, hand the manual to the user or purchaser for retention and instruct them in the efficient and safe operation of the appliance.

OPERATING INSTRUCTIONS

GRIDDLES

Griddle tops are designed to have food cooked directly on the surface. Do not put pots or pans on the griddle surface as this will scratch or nick the surface and will result in improper cooking or 4

Page 5
Image 5
Garland ECG Installation Procedure, Commissioning, Operating Instructions, All Models, Combustible Wall Minimum Clearance