3.3Audio Shield Termination
The audio shield wires should be terminated at the rear of the unit to the screws between J2401 and J2402 as shown in Figure
Rear View of backplate and rack
J2402 | J2401 |
Audio shields daisy chained and terminated using a lug attached to either of these screws.
Figure 3-1. Audio Shield Termination
3.4GMA 240 Installation
NOTE
Avoid installing the unit near heat sources. If this is not possible, ensure that additional cooling is provided. Allow adequate space for installation of cables and connectors. The installer will supply and fabricate all of the cables.
1.Assemble the connector/rack kit according to Tables
2.Slide the unit into the rack until the jackscrew makes contact with the receptacle located in the back plate.
3.Insert a 3/32” Allen wrench into the jackscrew access hole on the faceplate.
4.Turn the Allen wrench clockwise until the unit is secured in the rack. Continue turning until tight, but do not
CAUTION
Do not use excessive force when inserting the GMA 240 into the rack. This may damage the connectors, unit, and/or unit rack. If heavy resistance is felt during installation, stop, and remove the GMA 240 and identify the source of resistance.
5.To remove the unit from the rack, turn the Allen wrench counterclockwise until it disengages from the rack.
Page | GMA 240 Installation Manual |
Rev. A |