4. Choose from the following settings to adjust the filter:

 

 

 

 

Off— turn off the filter to make the display more sensitive to changes in the wind.

EN

 

On—select a higher number to increase how sensitively the display reacts to changes in the wind speed, or select a lower number to

 

 

 

decrease the sensitivity.

 

 

Auto—automatically adjusts the filter settings based on wind conditions.

 

 

Configuring the GWS 10 if the Filter and Offset Selections Are Not Shown

Refer to your Garmin Chartplotter or marine instrument owner’s manual for instructions on accessing configuration.

To configure the orientation:

1.Select Generic Configuration to specify data for the filter and offset settings.

2.Enter the following command: “ANGLEOFFSET=”

3.Follow the command with a number between 0 and 359, in degrees.

To configure the wind angle filter:

1.Select Generic Configuration to specify data for the filter and offset settings.

2.Enter the following command: “ANGLEFILTER=”

3.Follow the command with a number between 0 and 254, representing a time constant in increments of 0.25 second, or 255 to represent the automatic setting.

To configure the wind speed filter:

1.Select Generic Configuration to specify data for the filter and offset settings.

2.Enter the following command: “SPEEDFILTER=”

3.Follow the command with a number between 0 and 254, representing a time constant in increments of 0.25 second, or 255 to represent the Automatic setting.

NMEA 2000 PGN Information

Use the tables to determine the approved NMEA 2000 PGN information that can be received and transmitted by a GWS 10 when communicating with a NMEA 2000-compliant device.

Transmit

059392

ISO Acknowledgment

060928

ISO Address Claim

126208

NMEA - Command/Request/

 

Acknowledge Group Function

126464

Transmit/Receive PGN List Group

 

Function

126996

Product Information

130306

Wind Data

130312

Temperature

130314

Actual Pressure

Receive

059392

ISO Acknowledgment

059904

ISO Request

060928

ISO Address Claim

 

 

126208

NMEA - Command/Request/

 

Acknowledge Group Function

 

The GWS 10 is NMEA 2000

 

certified.

Specifications

Physical

note: The width of this sensor varies with the positioning of the wind vane.

Unit Dimensions:

W × H × D: 19 11/16 - 22 5/8 × 111/32 × 5 1/2 in. (500-575 × 280 × 140 mm)

Weight:

0.6 lb (0.275 kg)

Cable:

Attached NMEA 2000 cable length: 18 in. (46 cm)

Temperature Range:

5°F - 158°F (-15°C to 70°C)

Case Material

 

Housing and Base

PC/ABS

Wind vane and Anemometer

Polypropylene

GWS 10 installation instructions

EN–