4. Choose from the following settings to adjust the filter: |
|
|
|
| |
• Off— turn off the filter to make the display more sensitive to changes in the wind. | EN |
|
• |
| |
|
| |
decrease the sensitivity. |
|
|
• |
|
|
Refer to your Garmin Chartplotter or marine instrument owner’s manual for instructions on accessing configuration.
To configure the orientation:
1.Select Generic Configuration to specify data for the filter and offset settings.
2.Enter the following command: “ANGLEOFFSET=”
3.Follow the command with a number between 0 and 359, in degrees.
To configure the wind angle filter:
1.Select Generic Configuration to specify data for the filter and offset settings.
2.Enter the following command: “ANGLEFILTER=”
3.Follow the command with a number between 0 and 254, representing a time constant in increments of 0.25 second, or 255 to represent the automatic setting.
To configure the wind speed filter:
1.Select Generic Configuration to specify data for the filter and offset settings.
2.Enter the following command: “SPEEDFILTER=”
3.Follow the command with a number between 0 and 254, representing a time constant in increments of 0.25 second, or 255 to represent the Automatic setting.
NMEA 2000 PGN InformationUse the tables to determine the approved NMEA 2000 PGN information that can be received and transmitted by a GWS 10 when communicating with a NMEA
Transmit
059392 | ISO Acknowledgment |
060928 | ISO Address Claim |
126208 | NMEA - Command/Request/ |
| Acknowledge Group Function |
126464 | Transmit/Receive PGN List Group |
| Function |
126996 | Product Information |
130306 | Wind Data |
130312 | Temperature |
130314 | Actual Pressure |
Receive
059392 | ISO Acknowledgment |
059904 | ISO Request |
060928 | ISO Address Claim |
|
|
126208 | NMEA - Command/Request/ |
| Acknowledge Group Function |
| The GWS 10 is NMEA 2000 |
| certified. |
Physical
note: The width of this sensor varies with the positioning of the wind vane.
Unit Dimensions: | W × H × D: 19 11/16 - 22 5/8 × 111/32 × 5 1/2 in. |
Weight: | 0.6 lb (0.275 kg) |
Cable: | Attached NMEA 2000 cable length: 18 in. (46 cm) |
Temperature Range: | 5°F - 158°F |
Case Material |
|
Housing and Base | PC/ABS |
Wind vane and Anemometer | Polypropylene |