GarrettCom 6KQE manual B4.1 UL Requirements for DC-powered units

Models: 6KQE

1 50
Download 50 pages 5.34 Kb
Page 47
Image 47

Magnum 6KQE Managed Edge Switch Installation and User Guide

02/09

When power is applied, the green PWR LED will illuminate.

Note: The GND should be hooked up first. The 6KQE unit has a floating ground, so the user may elect to Ground either + or - terminal to suit the customer’s use.

Before connecting live power lines to the Terminal Block of –48VDC, 12VDC, 24VDC, 125VD or 250VDC products, always use a digital voltmeter to measure the output voltage of the power supply and determine the lead which is more “+ve potential”. The more “+ve” voltage lead from 48V or –48V supply must be connected to the post labeled “+”.

B4.1 UL Requirements for DC-powered units

CAUTION: 48VDC products shall be installed with a readily accessible disconnect device in the building installation supply circuit to the product.

Minimum 18AWG cable for connection to a Centralized DC power source.

1.Minimum 14AWG cable for connection to an earth wiring.

2.Use only with Listed 10A circuit breaker provided in building installation.

3.“Complies with FDA radiation performance standards, 21 CFR subchapter J.” or equivalent.

4.Fastening torque of the lugs on the terminal block: 9 inch-pound max.

5.To secure a centralized DC Power Source cable , use at least four cable ties to secure the cable to the rack at least 4 inches apart, with the first one located within 6 inches of the terminal block.

B5.0 OPERATION

Operation of Magnum 6KQE Switches with the optional -48VDC, 12VDC, 24VDC, 125VDC or 250VDC dual-source power input is identical to that of the standard single-source DC-powered models.

B6.0 TROUBLESHOOTING

Please refer to Section 6.0 for troubleshooting

www . GarrettCom . com

42

Page 47
Image 47
GarrettCom 6KQE manual B4.1 UL Requirements for DC-powered units