Magnum 6KQE Managed Edge Switch Installation and User Guide

02/09

The terminal block is located on the left front of the unit next to the Alarm terminal block and is equipped with four (4) screw-down lead posts. The primary terminals are identified as positive (A+),

negative (A-), and the secondary power terminals as negative (B-), positive (B+). The chassis is earth/ground (GND). The Dual Source terminal block for the 12, 24, 48, 125 and 250VDC are the same.

Note: The GND should be hooked up first. The 6KQE unit has a floating ground, so the user may elect to Ground either + or - terminal to suit the customer’s use. Before connecting live power lines to the terminal block, always use a digital voltmeter to measure the output voltage of the power supply and determine the lead which is more “+ve potential”. The more “+ve” voltage lead from a +ve or –ve power supply must be connected to the post labeled “+”.

The connection procedure is straightforward. Simply connect the DC leads to the Switch’s power terminals, positive (+) and negative (-) screws. The use of Ground (GND) is optional; it connects to the Switch chassis. Ensure that each lead is securely tightened.

C6.0 ORDERING INFORMATION FOR DUAL SOURCE POWER

To order the optional Dual-Source power supply factory installed, add “Dual- Src-xxxV” as a separate line item following the product model.

Example: Magnum 6KQE-48VDC

Dual-Src-48V

See the Configuration Guide on the GCI web site at http://www.garrettcom.com/techsupport/insertion_guides/6kqecg.pdf for additional information.