Magnum | Installation and User Guide (08/03) |
Conformal coating (tropical humidity protection) optional, request quote
Power Supply (Internal) 24VDC and -48VDC Power Supply
Power Input Voltage: 20 to 60 VDC
Power Consumption: 10 watts typical.
Power Supply (Ext.) 125VDC & 250VDC,
DC-DC Converter Rating: 5VDC, 3Amps
Power Supply (External) AC Power Supply
Input Frequency: 47 to 63 Hz
Power Consumption: 15 watts typical
Power Supply Rating: 3Amps at 5VDC
Network Cable Connectors
100Mbps: Category 5 UTP/STP, fiber (50/125, 62.5/125 mm, or
10 Mbps: Category 3, 4, 5 UTP (Note:
All the
Fiber Ports # 1 and 8
The switched fiber ports # 1 & 8 are fixed at
Mechanical
Enclosure: Rugged
See Section 3.1.2 for additional mounting details. Dimensions (wall mounted): 1.70 in D x 5.75 in W x 8.8 in H
(4.3 cm x 14.6 cm x 22.4 cm)
Weight: 3.5 lb. (1.6 kg.)
Cooling method: Convection, with case operating as a heat sink.
Note: Internal thermal materials and techniques (patent pending) conduct heat from the electronic elements inside to the steel case which acts as a heat sink. Internal chip temperatures are only about 10°C above case ambient at steady state operation
LED Indicators
PWR: Steady ON when power applied
SPEED: (when LINK is ON): ON = 100Mbps; OFF = 10 Mbps
LINK/ACT: Steady ON for LINK with no traffic, blinking indicates port is transmitting / receiving.
F/H
www . GarrettCom . com
3