Magnum P62-Series Hardened Switches | Installation and User Guide (08/03) |
3.2Connecting Ethernet Media, and Special Strain-relief feature
Note – see also “Cable Strain Relief Feature, Section 3.4.
The Magnum P62-Series Ethernet Switches (P62F model illustrated here) can be connected to the following three media types: 100BASE-TX, 10BASE-T and 100BASE-FX. CAT 5 cables should be used when making 100BASE-TX connections. When the ports are used as 10BASE-T ports, CAT 3 may be used. In either case, the maximum distance for unshielded twisted pair cabling is 100 meters (328 ft). For fiber port 100BASE-FX multi- mode, 50/125 or 62.5/125 microns
cabling can be used, whereas for single-mode, 9/125 microns cabling should be used. Fiber cabling supports much longer cable distances and higher bandwidth than copper wiring.
Media | IEEE Standard | Connector |
Twisted Pair (CAT 3 or 5) | 10BASE-T | RJ-45 |
Twisted Pair (CAT 5) | 100BASE-TX | RJ-45 |
Fiber (Multi-mode) | 100BASE-FX | SC |
Fiber (Single-mode) | 100BASE-FX | SC |
NOTE 1. : It is recommended that high quality CAT. 5 cables (which work for both 10 Mbps and 100Mbps) be used whenever possible in order to provide flexibility in a mixed- speed network, since P80-series switch ports are auto-sensing for either 10 and 100Mbps. Note that the auto-sensing function does not sense the cable type.
3.2.1Connect Twist Pair (RJ-45, CAT 3 or CAT 5, Unshielded or Shield)
The following procedure describes how to connect a 10BASE-T or 100BASE-TX twisted pair segment to the RJ-45 port. The procedure is the same for both unshielded and shielded twisted pair cables.
www . GarrettCom . com