1.2Ordering Information

Magnum P62-Series, 10/100 Ethernet Switch

Magnum P62F-AC-2MSC:P62F-AC Ethernet Switch with six 10/100 RJ-45 and two 100Mb FDX fiber multi-mode SC-type ports. Has 16KB address table and 1.0 MB packet buffers. AC power input, 85-160vac 47-63Hz worldwide auto-ranging via PSX-A power source Extended Temp ( a separate unit). Steel case used as a heat sink, designed for use in environmentally challenged locations such as “outdoors” with extended temperatures.

Magnum P62F-AC-1MISSC: Same as P62F-AC-2MSC, except one fiber port is 20km single-mode SC. (includes PSX-A unit)

Magnum P62F-AC-2SSC:Same as P62F-AC-2MSC, except both fiber ports are 20km single-mode SC. (includes PSX-A unit)

Magnum P62F-AC-NOF:P62F-DC Ethernet Switch, six 10/100 RJ-45 and no fiber ports. Has 16KB address table and 1.0MB packet buffers. AC power input 85- 260vac 47-63Hz worldwide auto-ranging, via PSX-A Power Source Extended Temp (a separate unit). Steel case used as a heat sink, designed for use in environmentally auto-ranging. Steel case used as a heat sink, designed for use in environmentally challenged locations such as “outdoors” with extended temperatures.

Magnum P62F-2MSC:8-port Ethernet Switch with two 100Mbps full-duplex switched fiber ports (multi-mode SC-type connector), and six half- or full-duplex switched RJ-45 10/100 auto-negotiating ports. Includes store-and-forward switching that filters and forwards data moving between the ports. The internal switch has 16K nodes address table and 1MB packet buffers. DC power input, 18-70VDC auto- ranging. Steel case acts as a heat sink. Rated for extended temperature.

Magnum P62F-1M1SSC:Same as P62F-2MSC, but with one multi-mode SC-type and one 20Km single mode SC fiber connectors.

Magnum P62F-2SSC:Same as P62F but with two 20Km sgl-mode SC-type fiber ports

Magnum P62F-NOF:P62F-DC Ethernet Switch, six 10/100 RJ-45 and no fiber ports. Has 16KB address table and 1.0MB packet buffers. DC power input, 18-70VDC auto-ranging. Steel case used as a heat sink, designed for use in environmentally challenged locations such as “outdoors” with extended temperatures.

Parts

Magnum P62F-5V-2MSC:Same as P62F-2MSC, except with 5VDC input using military-type-screw-lock connector.

Magnum P62F-5V-1M1SSC:Same as P62F-1,1SSC, except with 5VDC input using military-type-screw-lock connector.

Magnum P62F-5V-2SSC:Same as P62F-2SSC, except with 5VDC input using military-type-screw-lock connector.

Magnum P62F-5V-NOF: Same as P62F-NOF, except with 5VFC input via PSX-A using military-type screw lock connectors.

Magnum PSX-5V-CBL (spare): 2-ft power cord with military type screw-lock connector, spare for PSX to P62F-5V power cord.

Magnum PSX-A:P62F-5V Power Source for Extended Temperature, nominal AC input 115-240vac at 47-63HZ auto-ranging, 15 watts, 5VDC output at 3Amps. Steel case used as a heat sink. Extended temperature rated. Output power cord has military-style screw-lock plug. Mounts as a separate unit adjacent to a Magnum Model P62F-5V Switch.

Magnum PSX-T:Same as PSX-A , except 125VDC to 250VDC input, terminal lugs for “+”, “-“, and GND