GT150 F1 specifications
Power specifications
560W Power Supply
Operational Input | 100 to 240 |
|
|
|
|
|
|
Voltage Range |
|
|
|
|
|
|
|
(Vrms) |
|
|
|
|
|
|
|
Frequency | 60/50 |
|
|
|
|
|
|
Range (Nominal) |
|
|
|
|
|
|
|
(Hz) |
|
|
|
|
|
|
|
Nominal Input | 100 | 120 | 208 | 200 | 220 | 230 | 240 |
Voltage (Vrms) |
|
|
|
|
|
|
|
Max. Rated Output | 560 | 560 | 600 | 600 | 600 | 600 | 600 |
Wattage (Watts) |
|
|
|
|
|
|
|
Nominal Input | 6.5 | 6.5 | 3.5 | 3.5 | 3.5 | 3.5 | 3.5 |
Current (A rms) |
|
|
|
|
|
|
|
Max. Rated Input | 670 | 650 | 690 | 690 | 690 | 680 | 680 |
Wattage Rating |
|
|
|
|
|
|
|
(Watts) |
|
|
|
|
|
|
|
Max. Rated VA | 677 | 657 | 719 | 719 | 719 | 709 | 709 |
|
|
|
|
|
|
| |
Efficiency (%) at | 84 | 87 | 87 | 87 | 87 | 89 | 89 |
Max. Rated Output |
|
|
|
|
|
|
|
Wattage |
|
|
|
|
|
|
|
Power Factor | 0.99 | 0.99 | 0.96 | 0.96 | 0.96 | 0.96 | 0.96 |
Leakage Current | 0.5 | 0.5 | 1.0 | 1.0 | 1.0 | 1.0 | 1.0 |
(mA) |
|
|
|
|
|
|
|
Max. Inrush | Less | Less than | Less than | Less than | Less than | Less than | Less than |
Current (A peak) | than 30A | 30A | 30A | 30A | 30A | 30A | 30A |
Max. Inrush | 3.5 | 3.5 | 2.5 | 2.5 | 2.5 | 2.5 | 2.5 |
Current Duration |
|
|
|
|
|
|
|
(mS) |
|
|
|
|
|
|
|
Max. British | 2285 | 2285 | 2353 | 2353 | 2353 | 2319 | 2319 |
Thermal Unit |
|
|
|
|
|
|
|
Rating (BTU/hr) |
|
|
|
|
|
|
|