g

Digital EnergyGT Series

8 - Specifications

 

GT Model

 

 

1000T UL

 

 

1500T UL 2000T

 

3000T UL

 

 

 

 

 

 

 

1.5kVA/ 1200 W

 

 

 

Capacity

 

 

1kVA/800W

 

 

2kVA/1600W

 

3kVA/2400W

 

 

 

 

 

 

 

 

 

 

 

 

 

Rated Voltage

 

 

 

100V, 110V, 120V

 

 

 

 

 

 

 

Input

 

Voltage Range

80V~138V (full load); 65V ~80V (70% load)

 

 

 

 

 

 

 

 

 

 

 

Frequency

 

 

 

50Hz / 60Hz (± 4.8 Hz)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Power Factor

 

 

 

0.97

 

 

 

 

 

 

 

 

 

 

 

 

 

Voltage

 

 

 

100V, 110V, 120V

 

 

 

 

 

 

 

 

 

 

 

 

 

Frequency

 

 

 

50Hz / 60Hz

 

 

 

 

 

 

 

 

 

 

 

 

Voltage Regulation

 

± 2%

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Frequency Accuracy

 

 

 

± 0.05 Hz

 

 

 

 

 

 

 

 

 

 

 

Output

 

Wave Form

 

 

 

pure sine wave

 

 

 

 

 

 

 

 

 

 

 

Transient Response

 

 

 

 

 

 

 

 

± 8% (10% 90% linear load)

 

 

 

 

THD (linear load)

3%

 

 

3%

 

4%

 

 

 

THD (computer load)

 

 

 

6%

 

 

 

 

 

 

 

 

 

Overload Capacity

105%~125% for 3mins; 125%~150% for 30secs; >150% for 1sec

 

 

 

Crest Factor

 

3:1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Efficiency (AC-A C)

 

 

 

87%

 

 

 

 

 

 

 

 

 

 

 

Outlet

 

Receptacles

 

 

 

NEMA TYPE

 

 

 

 

 

 

 

 

 

 

 

 

 

Battery Voltage

36V

 

 

72V

 

72V

 

 

 

 

 

 

 

 

 

 

 

Battery

 

Battery Type (Lead acid)

12V/7Ah

 

 

12V/7Ah

 

12V/9A h

 

 

Back-up Time

 

 

 

5mins

 

 

 

 

(Typical)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Recharge Time

4~6 hours after complete discharge to recover 90%

 

Transfer

 

Transfer Time

 

 

 

zero

 

 

Time

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LED Status

On- line / Bypass / On- battery / Overload / Battery Low / Fault

 

LED

 

Battery Replace / Battery Level / Load Level

 

 

 

 

 

 

Alarm

 

 

 

buzzer

 

 

Interface

 

DB9

 

 

 

RS232/dry contact

 

 

 

 

 

 

 

 

 

 

 

 

SNMP Slot

 

 

 

internal

 

 

 

 

 

 

 

 

 

 

 

Noise (At 1 Meter)

40dB(A)

 

 

42dB(A)

 

45dB(A)

 

 

 

 

 

 

 

 

 

 

 

Environment

 

Operating

 

 

 

0~40°C (32~104°F)

 

 

 

 

Temper ature

 

 

 

 

 

 

 

 

 

Humidity

 

0%~90% (non-condensing)

 

 

 

 

Safety

 

 

 

UL/cUL

 

 

 

 

 

 

 

 

Safety

 

 

FCC Class A (2, 3kVA) /B (1kVA)

 

 

Approval

 

EMC

CISPR PUB 22 Class B; TUV/EMC; CE (1kVA)

 

 

 

 

CISPR PUB 22 Class A (2, 3kVA)

 

 

 

 

Lightning

 

 

 

IEEE 62.41 Category A

 

 

 

 

 

 

 

 

 

 

 

 

 

Battery Start

 

 

 

yes

 

 

Others

 

Extended Battery

yes (optional for longer runtime)

 

 

 

Bank

 

 

 

 

 

 

 

 

 

 

 

 

 

Long Time Model

 

 

 

yes (optional)

 

 

 

 

 

 

 

 

 

 

 

 

Dimensions

140x366x242 mm

 

 

140x425x373mm

 

Appearance

 

(W×D× H)

5.5x14.4x9.5 inch

 

 

5.5x16.7x14.7 inch

 

 

Weight

15 kg

 

 

30 kg

 

30 kg

 

 

 

 

 

 

 

 

 

33 lbs

 

 

66 lbs

 

66 lbs

 

 

 

 

 

 

 

OPM_GTU_TWR_1K0_3K0_XUS_V015

19

DE GT Series: User manual rev date 8-11- 04