Fan Switch

Fan Switch

 

 

 

 

 

 

Fan switch

 

 

 

 

 

 

 

 

 

 

 

9

 

 

 

 

 

ON

 

 

 

 

 

 

 

 

 

ON

 

 

 

OFF

 

 

 

 

 

 

 

 

 

OFF

 

 

 

Auxiliary Controls

Down/Off—Continuous Fan Up/On—Cycle Fan

The fan switch 9 is located behind the room cabinet.

This switch is set at continuous fan (down) at the factory to provide continuous fan operation in cool or heat modes. Leaving the switch in the continuous fan setting allows continuous circulation of room air and will result in a more balanced temperature throughout the room.

If you want the fan to cycle on and off with the compressor or with the heater, move the switch to cycle fan (up).

Freeze Sentinel

The Freeze Sentinel feature automatically turns on the resistance heater and fan if the room temperature (sensed at the unit) drops to approximately 40°F. It will turn the heater off when the temperature reaches about 45°F.

The Freeze Sentinel helps prevent plumbing damage in the room due to sub-freezing temperatures.

The Freeze Sentinel is active as long as power to the unit is on.