Operating Instructions Safety Instructions

About the controls on the air conditioner–models with touch pads.

Features and appearance will vary.

Air Conditioner Controls

Remote Control

Controls

Troubleshooting Tips Installation Instructions

ON/OFF Pad

Turns air conditioner on and off.

Display

Shows the set temperature or time remaining on timer.

MODE

Use to set the air conditioner to COOL or FAN mode.

Increase /Decrease Pads

Use to set temperature when in COOL mode.

FAN Pad

Use to set the fan speed to LOW (F1), MED (F2) or HIGH (F3).

ENERGY SAVER–Controls the fan.

ON–The fan and compressor cycle on and off. This results in wider variations of room temperature and humidity. Normally used when the room is unoccupied. Note: The fan will continue to run for a short time after the compressor cycles off.

OFF–The fan runs all the time, while the compressor cycles on and off.

This switch must be set at OFF in order to use the fan settings (on the mode control).

CIRCULAIRE

For continuous side-to-side air circulation (cool settings only), set the Circulaire switch to ON.

For fixed side-to-side air direction, turn ON until the desired air direction is obtained, then turn it OFF.

TIMER Pad

ON–When the air conditioner is off, it can be set to automatically come on in 1 to 12 hours at its previous setting. Each touch will set the timer in hours.

OFF–When the air conditioner is on, it can be set to automatically turn off in 1 to 12 hours. Each touch will set the timer in hours. After the timer has been on for 30 minutes, the temperature will automatically rise 2°F, and after another 30 minutes, it will automatically rise 2°F again. The temperature will then stay the same until the timer goes OFF.

To cancel the timer, press the TIMER pad until the display time disappears.

Remote Control Signal Receiver

Consumer Support

Remote Control

To ensure proper operation, aim the

Make sure nothing is between the air

remote control at the signal receiver

conditioner and the remote control

on the air conditioner.

that could block the signal.

The remote control signal has a range of up

Make sure batteries are fresh and installed

to 21 feet.

correctly–see the Care and Cleaning section.

4

Page 4
Image 4
GE AG_07 operating instructions Consumer Support, Remote Control

AG_07 specifications

The GE AG_07 is a sophisticated gas turbine designed to set new standards in energy efficiency and operational flexibility. This advanced turbine is part of GE's Aeroderivative Gas Turbine (AGT) family, which is well-known for its high performance and adaptability. With its innovative design and cutting-edge technologies, the AG_07 has become a cornerstone for power generation in diverse applications, including industrial, peaking, and renewables integration.

One of the key features of the GE AG_07 is its exceptional thermal efficiency. This turbine boasts a thermal efficiency of up to 39 percent in simple cycle and can achieve even higher efficiencies in combined cycle operations. This efficiency translates into lower fuel consumption and reduced greenhouse gas emissions, making it an environmentally friendly choice for power generation.

The AG_07 is also equipped with advanced aerodynamics and combustor technology. It incorporates a lean-premix combustion system that allows for stable combustion at a wide range of operating conditions. This system minimizes nitrogen oxide (NOx) emissions, adhering to stringent environmental regulations while also contributing to the turbine's overall efficiency. Moreover, the turbine utilizes advanced turbine cooling techniques to maintain optimal operating temperatures and enhance durability.

Another notable characteristic of the AG_07 is its compact and modular design. This design not only simplifies installation and maintenance but also enables the turbine to be easily integrated into existing power plants. It is particularly suited for applications that require quick ramp-up capabilities, making it an ideal choice for peaking power plants and backup generation systems.

In terms of technology, the AG_07 benefits from GE’s digital solutions. It is embedded with advanced sensors and predictive maintenance capabilities that allow operators to monitor performance in real time. This digital intelligence helps to optimize operations, reduce downtime, and extend the lifespan of the turbine.

Additionally, the GE AG_07 is designed to support a wide variety of fuels, from natural gas to biofuels, enhancing its flexibility in meeting different energy demands. This flexibility is crucial in today’s dynamic energy landscape, where the integration of renewable energy sources is becoming increasingly important.

Overall, the GE AG_07 gas turbine stands out for its high efficiency, low emissions, modular design, and advanced technologies. As energy needs continue to evolve, the AG_07 is well-positioned to meet the challenges of modern power generation while supporting a cleaner, more sustainable future.