When the air conditioner is turned on, it will

Lights next to the touch pads on the air conditioner

automatically start in the last cool and fan

control panel indicate the selected settings.

settings used.

 

Safety Instructions

COOL Mode

Use the COOL mode with HIGH (F3), MED (F2) or LOW (F1) fan for cooling. Use the INCREASE / DECREASE pads to set the desired temperature between 60°F and 86°F in 1°F increments.

A thermostat is used to maintain the room temperature. The compressor will cycle on and off to keep the room at the set level of comfort. Set the thermostat at a lower number and the indoor air will become cooler. Set the thermostat at a higher number and the indoor air will become warmer.

NOTE: If the air conditioner is off and is then turned on while set to COOL, it will take approximately 3 minutes for the compressor to start and cooling to begin.

Cooling Descriptions

For Normal Cooling–Select the COOL mode and HIGH (F3) or MED (F2) fan with a middle set temperature.

For Maximum Cooling–Select the COOL mode and HIGH (F3) fan with a lower set temperature.

For Quieter & Nighttime Cooling–Select the COOL mode and LOW (F1) fan with a middle set temperature.

NOTE: If you switch from a COOL setting to OFF or to a fan setting, wait at least 3 minutes before switching back to a COOL setting.

Operating Instructions

FAN Mode

Use the FAN at HIGH (F3), MED (F2) or LOW (F1) to provide air circulation and filtering without cooling. Since fan only settings do not provide cooling,

a temperature setting will not be displayed.

Vent Control

The vent control is located above the control panels.

When set at CLOSE, only the air inside the room will be circulated and conditioned. When set at OPEN, some inside air is exhausted outside.

To open the vent, pull the lever toward you.

To close it, push it in.

Air Direction – Side-to-Side

The side-to-side air direction is adjusted by moving the lever to the left or right.

Air Direction – Up and Down

Fingertip pressure on the horizontal louvers

(on some models)

adjusts the air direction up or down.

 

5

Installation Instructions Troubleshooting Tips Consumer Support

Page 5
Image 5
GE AG_07 operating instructions Cool Mode, FAN Mode, Vent Control, Air Direction Side-to-Side, Air Direction Up and Down

AG_07 specifications

The GE AG_07 is a sophisticated gas turbine designed to set new standards in energy efficiency and operational flexibility. This advanced turbine is part of GE's Aeroderivative Gas Turbine (AGT) family, which is well-known for its high performance and adaptability. With its innovative design and cutting-edge technologies, the AG_07 has become a cornerstone for power generation in diverse applications, including industrial, peaking, and renewables integration.

One of the key features of the GE AG_07 is its exceptional thermal efficiency. This turbine boasts a thermal efficiency of up to 39 percent in simple cycle and can achieve even higher efficiencies in combined cycle operations. This efficiency translates into lower fuel consumption and reduced greenhouse gas emissions, making it an environmentally friendly choice for power generation.

The AG_07 is also equipped with advanced aerodynamics and combustor technology. It incorporates a lean-premix combustion system that allows for stable combustion at a wide range of operating conditions. This system minimizes nitrogen oxide (NOx) emissions, adhering to stringent environmental regulations while also contributing to the turbine's overall efficiency. Moreover, the turbine utilizes advanced turbine cooling techniques to maintain optimal operating temperatures and enhance durability.

Another notable characteristic of the AG_07 is its compact and modular design. This design not only simplifies installation and maintenance but also enables the turbine to be easily integrated into existing power plants. It is particularly suited for applications that require quick ramp-up capabilities, making it an ideal choice for peaking power plants and backup generation systems.

In terms of technology, the AG_07 benefits from GE’s digital solutions. It is embedded with advanced sensors and predictive maintenance capabilities that allow operators to monitor performance in real time. This digital intelligence helps to optimize operations, reduce downtime, and extend the lifespan of the turbine.

Additionally, the GE AG_07 is designed to support a wide variety of fuels, from natural gas to biofuels, enhancing its flexibility in meeting different energy demands. This flexibility is crucial in today’s dynamic energy landscape, where the integration of renewable energy sources is becoming increasingly important.

Overall, the GE AG_07 gas turbine stands out for its high efficiency, low emissions, modular design, and advanced technologies. As energy needs continue to evolve, the AG_07 is well-positioned to meet the challenges of modern power generation while supporting a cleaner, more sustainable future.