Window Requirements

■ These instructions are for a standard double-

hung window. You will need to modify them for

other types of windows.

■ The air conditioner can be installed without the sliding panels if needed to fit in a narrow window. See the window opening dimensions to the right.

■ All supporting parts must be secured to firm wood, masonry or metal.

■ The electrical outlet must be within reach of the power cord. Do not use an extension cord.

13″ min.

22″ to 36″

(with sliding panels)

18 3⁄4″ min.

(without sliding panels)

Safety Instructions Operating Instructions

2

Storm Window Requirements

A storm window frame will not allow the air

conditioner to tilt towards the outside and will

 

keep it from draining properly. To adjust for this,

 

attach a piece of wood to the stool.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Wood

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1/2″ higher

 

 

 

 

 

 

 

 

 

 

 

 

 

 

than frame

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Stool

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Storm window

 

 

 

 

 

frame

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WOOD PIECES—

WIDTH: 2″

LENGTH: Long enough to fit inside the window frame.

THICKNESS: To determine the thickness, place a piece of wood on the stool to make it 1/2″ higher than the top of the storm window frame.

Attach securely with nails or screws provided by the installer.

Installation Instructions Troubleshooting

Prepare the Window and the Case

3

 

Cut the window sash seal to the proper length.

 

Insert the sliding panels into the guides of the

A

B

Peel off the backing and attach the seal to the

air conditioner and attach them to the case

 

 

 

 

underside of the window sash.

 

with 8 Type B screws, 4 on each side.

Sash

Seal

Use Type B screws.