Through-the-Wall Installation
The case may be installed
Read completely, then follow
IMPORTANT:
1 | ■ Any side louvers must project on the outdoor side of the wall. | ||
■ The room side of the case must project into the room at least 1 1/2″ from the finished wall. | |||
| ■ The case must be installed level from | ||
|
|
| Remove the air conditioner from the case. |
|
| A | |
|
|
| For specific instructions, refer to the Window |
|
|
| |
|
|
| Installation Instructions. |
|
|
| Make certain a wall receptacle is available close |
|
| B | |
|
|
| to the hole location or make arrangements to |
|
|
| |
|
|
| install a receptacle. |
|
|
| Determine the size of wall opening by adding |
|
| C | |
|
|
| 1/8″ to the height and width of the case. |
|
|
| |
|
|
| Measure height from the top of the case to the |
|
|
| bottom of the rail. |
|
|
| Place the case in the wall opening and secure |
|
| D | |
|
|
| the bottom rail, case sides and top with 12 |
|
|
| |
|
|
| 1″ long #10 wood screws. |
| NOTE: Drill pilot holes, if necessary, for proper | ||
| installation. If the frame is oversized, use shims to | ||
| prevent case distortion. | ||
|
| ||
2 | Finish the Wall Opening | ||
Caulk all four sides on the outdoor side of the case to prevent moisture from getting through to the | |||
interior wall. Use of flashing (drip rail) will further prevent water from dripping inside the wall and down |
the outside of the building.
Safety Instructions Operating Instructions Installation Instructions
Brick veneer
Lintel angle
(if required) Caulking
Holes for
#10 1″ long
wood
screws
Flashing (drip rail)
Caulking
Plaster line
Trim molding (if desired)
Roomside
Caulking (between bottom rail and flashing)
11/2″ min.
Troubleshooting Tips
Customer Service