Performance Data Sheet

Model: GE RPWF

Use Replacement Cartridge RPWF.

The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system as specified in NSF/ANSI Standard 42 and Standard 53. System tested and certified by NSF International against NSF/ANSI Standard 42 and Standard 53 for the reduction of substances listed below.

Capacity 170 Gallons (643.5 Liters). Contaminant Reduction Determined by NSF testing.

 

 

 

 

Average Product

Max Permissible

 

 

Substance Tested

 

NSF specified

Avg %

Water

Product Water

NSF Reduction

NSF

for Reduction

Average Influent

Challenge Concentration

Reduction

Concentration

Concentration

Requirements

Test Report

Chlorine Taste and Odor

2.0 mg/L

2.0 mg/L ± 10%

97.4%

0.05 mg/L

N/A

≥50%

J-00102044

Nominal Particulate

 

 

 

 

 

 

 

Class I, , ≥0.5 to < 1.0 μm

7,633,333 pts/mL

At least 10,000 particles/mL

99.0%

71,850 pts/ml

N/A

≥85%

J-00106249

Asbestos

109 MFL

107 to 108 fibers/L; fi bers

 

 

 

 

 

greater than 10μm in length

99.99%

<1 MFL

N/A

≥99%

J-00102069

Atrazine

0.009 mg/L

0.009 mg/L ± 10%

94.4%

0.0005 mg/L

0.003 mg/L

N/A

J-00102058

Benzene

0.016 mg/L

0.015 mg/L ± 10%

96.4%

0.001 mg/L

0.005 mg/L

N/A

J-00102065

Carbofuran

0.08 mg/L

0.08 mg/L ± 10%

98.8%

0.001 mg/L

0.04 mg/L

N/A

J-00102059

Cyst*

104,750 cysts/L

Minimum 50,000 cysts/L

99.99%

3 cyst/L

N/A

≥99.95%

J-00102057

Lead pH @6.5

0.140 mg/L

0.15 mg/L ± 10%

99.3%

0.001 mg/L

0.010 mg/L

N/A

J-00102052

Lead pH @8.5

0.158 mg/L

0.15 mg/L ± 10%

98.3%

0.002 mg/L

0.010 mg/L

N/A

J-00102053

Mercury @ pH 6.5

0.006 mg/L

0.006 mg/L ± 10%

91%

0.0003 mg/L

0.002 mg/L

N/A

J-00102054

Mercury @ pH 8.5

0.006 mg/L

0.006 mg/L ± 10%

88.3%%

0.0007 mg/L

0.002 mg/L

N/A

J-00104087

Lindane

0.002 mg/L

0.002 mg/L ± 10%

99%

0.00002 mg/L

0.0002 mg/L

N/A

J-00102063

P-Dichlorobenzene

0.222 mg/L

0.225 mg/L ± 10%

99.8%

0.0005 mg/L

0.075 mg/L

N/A

J-00102067

Toxaphene

0.015 mg/L

0.015 mg/L ± 10%

93.5%

0.001 mg/L

0.003 mg/L

N/A

J-00102061

2, 4-D Reduction

0.218 mg/L

0.210 mg/L±10%

99.9%

0.0001 mg/L

0.07 mg/L

N/A

J-00102064

VOC

0.278 mg/L

0.300 mg/L ± 10%

97.7%

0.0015 mg/L

N/A

≥95%

J-00102070

*Based on the use of Cryptosporidium parvum oocysts.

The following pharmaceutical reduction claims have not been certified by NSF International. Claims tested and verified by independent laboratory:

 

 

 

 

 

Max Permissible

 

Contaminant

 

NSF specified

Avg %

Average Product Water

Product Water

NSF

Reduction

Average Influent

Challenge Concentration

Reduction

Concentration

Concentration

Test Report

Atenolol

1088 ng/L

N/A

99.5%

5.0 ng/L

N/A

J-00103221

Fluoxetine

845 ng/l

N/A

99.4%

5.0 ng/L

N/A

J-00103221

Ibuprofen

898 ng/L

N/A

98.8%

9.9 ng/L

N/A

J-00103726

Progesterone

945 ng/L

N/A

99.4%

5.5 ng/L

N/A

J-00103727

Trimethoprim

403 ng/L

N/A

99.5%

2.0 ng/L

N/A

J-00103221

Application Guidelines/Water Supply Parameters

Service Flow

0.5 gpm (1.89 lpm)

Water Supply

Potable Water

Water Pressure

25-120 psi (172– 827 kPa)

Water Temperature

33º F - 100º F (0.6º C - 38º C)

It is essential that the manufacturer’s recommended installation, maintenance and filter replacement requirements be carried out for the product to perform as advertised. See Installation Manual for Warranty information.

Note: While the testing was performed under standard laboratory conditions, actual performance may vary.

Replacement Cartridge: RPWF. For estimated costs of replacement elements please call 1-800-626-2002 or visit our website at www.geapplianceparts.com.

WARNING

To reduce the risk associated with ingestion of contaminants:

ADo not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before and after the system. Systems certified for cyst reduction may be used on disinfected water that may contain filterable cysts. EPA Establishment Number 070595-MEX-001.

exceeds 80 psi, you must install a pressure-limiting valve. Contact a plumbing professional if you are uncertain how to check your water pressure.

KDo not install where water hammer conditions may occur. If water hammer conditions exist you must install a water hammer arrester. Contact a plumbing professional if you are uncertain how to check for this condition.

KDo not install on hot water supply lines. The maximum operating water temperature of this filter system is 100º F (38º C).

KProtect filter from freezing. Drain filter when temperatures drop below 33ºF (0.6ºC).

K The disposable filter cartridge must be replaced every 6 months at the rated capacity, or sooner if a noticeable reduction in flow rate occurs.

NOTICE

To reduce the risk associated with property damage due to water leakage: DRead and follow use instructions before installation and use of this system. D5stallation and use MUST comply with all state and local plumbing codes.

DDo not install if water pressure exceeds 120 psi (827 kPa). If your water pressure

For conditions of use, health claims certified by the California Department of Public Health, and replacements, see performance data sheet. California Department of Public Health Certification #11-2110. The contaminants or other substances removed or reduced by this water filter are not necessarily in all users’ water.

GE

Appliances Appliance Park Louisville, KY 40225 geapplianceparts.com

System tested and certified by NSF International against NSF/ANSI Standard 42 and Standard 53 in model GE RPWF for the reduction of the claims specifi ed

REPLACEMENT on the performance data sheet.

ELEMENT

34-8708-7119-0 EPA #070595-MEX-001 © 2012 General Electric Company PC71879

45

Page 45
Image 45
GE installation instructions Performance Data Sheet Model GE Rpwf

GE specifications

General Electric, commonly referred to as GE, is a global conglomerate with a diverse portfolio that encompasses several industries including aviation, healthcare, power, renewable energy, and manufacturing. Founded in 1892, GE has established itself as a leader in technology and innovation, driven by a commitment to deliver cutting-edge solutions that address the world’s most pressing challenges.

One of the hallmark features of GE is its strong emphasis on research and development. The company invests billions of dollars each year in R&D, fostering innovation across its various business sectors. This focus on technological advancement has resulted in a myriad of breakthroughs, such as GE's development of advanced jet engines that significantly improve fuel efficiency and reduce emissions, setting new standards in the aviation industry.

In healthcare, GE has revolutionized medical imaging and diagnostic technologies. With products such as MRI machines and ultrasound equipment, GE has led the way in providing high-quality imaging solutions that enhance patient care. The company’s digital healthcare technologies leverage artificial intelligence to improve diagnostics and streamline operations for healthcare providers, ultimately enhancing patient outcomes.

In the energy sector, GE is at the forefront of the shift toward renewable energy. The company develops wind turbines, gas turbines, and energy storage solutions that integrate with traditional power sources to create a more sustainable energy landscape. GE’s commitment to reducing carbon emissions is evident in its innovative technologies that harness the power of wind, solar, and hydroelectric energy.

GE’s digital industrial transformation is another defining characteristic, as it integrates the Internet of Things (IoT) into its operations and product offerings. Through the use of advanced data analytics and machine learning, GE is creating smart and connected solutions that enhance operational efficiency and predictive maintenance across industries.

The company's global presence and commitment to sustainability also contribute to its reputation as a responsible corporate citizen. GE has implemented initiatives to reduce its environmental footprint and improve community engagement around the world.

In summary, General Electric’s main features include its strong focus on R&D, revolutionary healthcare technologies, leadership in renewable energy, digital industrial transformation, and a commitment to sustainability. With a rich history and a forward-looking approach, GE continues to shape industries and improve lives through innovation.