Dimensions and Installation Information (in inches)
For answers to your Monogram,® GE Profile or
GE® appliance questions, visit our website at
ge.com or call GE Answer Center® service,
800.626.2000.
As an EnErgy StAr®
partner, gE has determined
that this product meets the
EnErgy StAr guidelines
for energy efficiency.
Specification Created 9/06 350233
Panel
Thickness
Kit A B C
GPF525 25-1/4" 23-1/2" N/A 1/4"
GPF575 25-1/2" 23-5/8" 1/4" 3/4"
Listed by
Underwriters
Laboratories
• The rough cabinet opening must be at least 24" deep,
24" wide and approximately 34-1/2" high from floor to
underside of the countertop.
4"6"5" 5"4"
Figure A
Floor MUST be Even
With Room Floor
Cabinets
Square
and
Plumb
This Wall Area
must be Free
of Pipes or
wires
24" Min.24" Min.
34-1/2"1/4"
Underside of
Countertop
to Floor
Plumbing and Electric Service
Must Enter Inside This Area

24

25

MAX.

20-1/2

4

4 (Adjustable)

33-3/4" MIN.

adj. to 35"

27-1/2

22
B
See Detail E for 3/4" Panel Detail E for 3/4 panel only
Door insert ABack ViewFront View
F
F
1-7/8 1-7/8
20
Section E-F
C
3/8
3/4
B
See Detail E for 3/4" Panel Detail E for 3/4 panel only
Door insert ABack ViewFront View
F
F
1-7/8 1-7/8
20
Section E-F
C
3/8
3/4
Electrical Rating
Voltage AC.......................................................... 120
Hertz..................................................................... 60
Total connected load amperage............. 10
Calrod® heater watts max........................ 875
For use on adequately wired 120-volt,
15-amp circuit having 2-wire service
with a separate ground wire. This appliance
must be grounded for safe operation.
Note: The rough cabinet opening must be at
least 24" deep, 24" wide and approximately
34-1/2" high from floor to underside of
the countertop. Dishwasher must not be
installed more than 10 feet from sink for
proper drainage. All p lumbing and
electrical work mus t be in accordance
with local codes. T he power cord and
connections must com ply with the Nati onal
Electrical Code Sec tion 422 and/or local
codes and ordinances. The cord must be no
longer than 6 ft. from the junction box to
the receptacle.
Installation Information: Before installing,
consult installation instructions packed with
product for current dimensional data.
GLD4600/50/60N

GE® Tall Tub Built-In Dishwasher