SmartWater Filtration System GNSV70FBL and GNSV75FWW

Using Filter FQSVF

This System has been tested according to NSF/ANSI 42 and 53 for the reduction of the substances listed below. The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system, as specified in NSF/ANSI 42 and 53.

Actual performance may vary with local water conditions.

Do not use with water that is microbiologically unsafe or with water of unknown quality without adequate disinfection before or after the system. Systems certified for cyst reduction may be used on disinfected waters that may contain filterable cysts.

Standard No. 42: Aesthetic Effects

 

USEPA

Influent

Influent

Effluent

 

 

% Reduction

Min. Required

 

 

 

 

 

Parameter

MCL

Challenge Concentration

Average

Average

Maximum

Average

Minimum

Reduction

Chlorine

2.0 mg/L ± 10%

1.94 mg/L

<0.05 mg/L

<0.05 mg/L

97.41%

97.22%

>50%

T & O

Particulate**

≥ 10000 particles

4100000 #/mL

24400 #/mL

67000 #/mL

99.35%

97.84%

>85%

 

 

 

Standard No. 53: Health Effects

 

 

 

 

Turbidity

1 NTU***

11 ± 1 NTU***

11.08 NTU

0.21 NTU

0.38 NTU

98.04%

96.20%

0.5 NTU

Cysts

99.95% red.

Min. 50000L

141750 #/L

<1 #/L

2 #/L

>99.99%

>99.99%

>99.95%

Asbestos

99% red.

107 and 108 fibers/L;

168 MF/L

0.99885891 MF/L

<1 MF/L

99.89%

99.82%

>99%

 

 

fibers >10 µm long

 

 

 

 

 

 

Lead,

0.015 mg/L

0.15 mg/L ± 10%

0.147 mg/L

<0.001 mg/L

<0.001 mg/L

99.32%

99.29%

0.010 mg/L

pH 6.5

 

 

 

 

 

 

 

 

Lead,

0.015 mg/L

0.15 mg/L ± 10%

0.143 mg/L

<0.001 mg/L

<0.001 mg/L

99.30%

99.29%

0.010 mg/L

pH 8.5

 

 

 

 

 

 

 

 

Mercury,

0.002 mg/L

0.006 mg/L ± 10%

0.006033333 mg/L

<0.0002 mg/L

<0.0002 mg/L

96.68%

96.49%

0.002 mg/L

pH 6.5

 

 

 

 

 

 

 

 

Mercury,

0.002 mg/L

0.006 mg/L ± 10%

0.0058 mg/L

0.000333 mg/L

0.0005 mg/L

94.34%

92.06%

0.002 mg/L

pH 8.5

 

 

 

 

 

 

 

 

Lindane

0.0002 mg/L

0.002 mg/L ± 10%

0.002016667 mg/L

<0.00002 mg/L

<0.00002 mg/L

99.00%

98.95%

0.0002 mg/L

Benzene

0.001 mg/L

0.015 mg/L ± 10%

0.01417 mg/L

0.000500 mg/L

0.000500 mg/L

96.47%

96.43%

0.005 mg/L

Atrazine

0.003 mg/L

0.009 mg/L ± 10%

0.00830 mg/L

0.002000 mg/L

0.002000 mg/L

74.82%

61.54%

0.003 mg/L

VOC Reduction

 

 

 

 

 

 

 

 

Chloroform

0.080 mg/L

0.30 ± 10%

0.31429 mg/L

0.00186429 mg/L

0.0055 mg/L

99.40%

98.28%

95%

*Tested using a flow rate of 0.60 gpm (2.27 l/min); pressure of 60 psig; pH of 7.5 ± 0.5; temp. of 68° ± 5°F (20° ± 3°C) **Measurement in particles/mL. Particles used were 0.5–1 microns.

***NTU—Nephelometric Turbidity Units

Operating Specifications

Capacity: certified for up to 160 gallons (605 l); up to six months

Pressure requirement: 35–120 psi (2.8–8.2 bar)

Temperature: 33–100°F (0.6–38°C)

Flow rate: 0.60 gpm (2.27 l/min)

Replacement Filter Canisters/Estimated Replacement Costs

FQSVF—Replacement filter canister $35–40

For replacement parts, call toll-free 800.626.2002 (U.S.), 800.663.6060 (Canada–English), 800.361.3869 (Canada–French)

 

State of California

 

Department of Health Services

 

Water Treatment Device

 

Certificate Number

 

04 - 1601

 

Date Issued: February 9, 2004

 

 

 

 

Trademark/Model Designation

Replacement Element(s)

GXSV65 F

FQSVF

GQSV65 F

FQSVF

GNSV70 FBL

FQSVF

GNSV75 FWW

FQSVF

Manufacturer: General Electric Company

The water treatment device(s) listed on this certificate have met the testing requirements pursuant to Section

116830 of the Health and Safety Code for the following health related contaminants:

Microbiological Contaminants and Turbidity

Inorganic/Radiological Contaminants

Cysts

 

Asbestos

 

Turbidity

 

Lead

 

Organic Contaminants

 

Mercury

 

 

 

 

Atrazine

 

 

 

Lindane

 

 

 

Benzene

 

 

 

VOCs

Endrin

 

Simazine

Alachlor

 

Atrazine

Ethylbenzene

 

Styrene

EDB

 

Benzene

 

1,1,2,2-Tetrachloroethane

Haloacetonitriles (HAN)

Carbofuran

Bromochloroacetonitrile

Tetrachloroethylene

Carbon Tetrachloride

Dibromoacetonitrile

Toluene

Chlorobenzene

Dichloroacetonitrile

2,4,5-TP (Silvex)

Chloropicrin

Trichloroacetonitrile

Tribromoacetic Acid

2,4-D

Haloketones (HK)

 

1,2,4-Trichlorobenzene

1,1-Dichloro-2-Propanone

DBCP

1,1,1-Trichloroethane

1,1,1-Trichloro-2-Propanone

o-Dichlorobenzene

1,1,2-Trichloroethane

Heptachlor

 

p-Dichlorobenzene

Heptachlor Epoxide

 

Trichloroethylene

1,2-Dichloroethane

Hexachlorobutadiene

Trihalomethanes (THMs)

1,1-Dichloroethylene

Hexachlorocyclopentadiene

Bromodichloromethane

cis-1,2-Dichloroethylene

Lindane

 

Bromoform

Methoxychlor

 

trans-1,2-Dichloroethylene

 

Chloroform

Pentachlorophenol

 

1,2-Dichloropropane

 

 

Chlorodibromomethane

cis-1,3-Dichloropropylene

 

 

Xylenes

Dinoseb

 

 

 

 

 

 

Rated Service Capacity: 160 gal

 

Rated Service Flow: 0.6 gpm

Do not use where water is microbiologically unsafe or with water of unknown quality, except that systems certified for cyst reduction may be used on disinfected waters that may contain filterable cysts.

IOWA RESIDENTS ONLY:

Store or Seller’s Name

Address

City

State

Zip

Telephone

 

 

 

 

Seller’s signature

 

 

 

 

 

 

 

Customer’s signature

 

Date

 

4

Page 4
Image 4
GE GNSV70FBL owner manual Performance Data Sheet, Using Filter FQSVF