![Performance Data Sheet.](/images/new-backgrounds/63702/637027x1.webp)
Performance Data Sheet.
SmartWater Filtration System GNSV70FBL and GNSV75FWW
Using Filter FQSVF
■This System has been tested according to NSF/ANSI 42 and 53 for the reduction of the substances listed below. The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system, as specified in NSF/ANSI 42 and 53.
■Actual performance may vary with local water conditions.
■Do not use with water that is microbiologically unsafe or with water of unknown quality without adequate disinfection before or after the system. Systems certified for cyst reduction may be used on disinfected waters that may contain filterable cysts.
Standard No. 42: Aesthetic Effects
| USEPA | Influent | Influent | Effluent |
|
| % Reduction | Min. Required |
|
|
|
|
| ||||
Parameter | MCL | Challenge Concentration | Average | Average | Maximum | Average | Minimum | Reduction |
Chlorine | — | 2.0 mg/L ± 10% | 1.94 mg/L | <0.05 mg/L | <0.05 mg/L | 97.41% | 97.22% | >50% |
T & O | — | — | — | — | — | — | — | — |
Particulate** | — | ≥ 10000 particles | 4100000 #/mL | 24400 #/mL | 67000 #/mL | 99.35% | 97.84% | >85% |
|
|
| Standard No. 53: Health Effects |
|
|
|
| |
Turbidity | 1 NTU*** | 11 ± 1 NTU*** | 11.08 NTU | 0.21 NTU | 0.38 NTU | 98.04% | 96.20% | 0.5 NTU |
Cysts | 99.95% red. | Min. 50000L | 141750 #/L | <1 #/L | 2 #/L | >99.99% | >99.99% | >99.95% |
Asbestos | 99% red. | 107 and 108 fibers/L; | 168 MF/L | 0.99885891 MF/L | <1 MF/L | 99.89% | 99.82% | >99% |
|
| fibers >10 µm long |
|
|
|
|
|
|
Lead, | 0.015 mg/L | 0.15 mg/L ± 10% | 0.147 mg/L | <0.001 mg/L | <0.001 mg/L | 99.32% | 99.29% | 0.010 mg/L |
pH 6.5 |
|
|
|
|
|
|
|
|
Lead, | 0.015 mg/L | 0.15 mg/L ± 10% | 0.143 mg/L | <0.001 mg/L | <0.001 mg/L | 99.30% | 99.29% | 0.010 mg/L |
pH 8.5 |
|
|
|
|
|
|
|
|
Mercury, | 0.002 mg/L | 0.006 mg/L ± 10% | 0.006033333 mg/L | <0.0002 mg/L | <0.0002 mg/L | 96.68% | 96.49% | 0.002 mg/L |
pH 6.5 |
|
|
|
|
|
|
|
|
Mercury, | 0.002 mg/L | 0.006 mg/L ± 10% | 0.0058 mg/L | 0.000333 mg/L | 0.0005 mg/L | 94.34% | 92.06% | 0.002 mg/L |
pH 8.5 |
|
|
|
|
|
|
|
|
Lindane | 0.0002 mg/L | 0.002 mg/L ± 10% | 0.002016667 mg/L | <0.00002 mg/L | <0.00002 mg/L | 99.00% | 98.95% | 0.0002 mg/L |
Benzene | 0.001 mg/L | 0.015 mg/L ± 10% | 0.01417 mg/L | 0.000500 mg/L | 0.000500 mg/L | 96.47% | 96.43% | 0.005 mg/L |
Atrazine | 0.003 mg/L | 0.009 mg/L ± 10% | 0.00830 mg/L | 0.002000 mg/L | 0.002000 mg/L | 74.82% | 61.54% | 0.003 mg/L |
VOC Reduction |
|
|
|
|
|
|
|
|
Chloroform | 0.080 mg/L | 0.30 ± 10% | 0.31429 mg/L | 0.00186429 mg/L | 0.0055 mg/L | 99.40% | 98.28% | 95% |
*Tested using a flow rate of 0.60 gpm (2.27 l/min); pressure of 60 psig; pH of 7.5 ± 0.5; temp. of 68° ± 5°F (20° ± 3°C) **Measurement in particles/mL. Particles used were
Operating Specifications
Capacity: certified for up to 160 gallons (605 l); up to six months
Pressure requirement:
Temperature:
Flow rate: 0.60 gpm (2.27 l/min)
Replacement Filter Canisters/Estimated Replacement Costs
For replacement parts, call
| State of California |
| Department of Health Services |
| Water Treatment Device |
| Certificate Number |
| 04 - 1601 |
| Date Issued: February 9, 2004 |
|
|
|
|
Trademark/Model Designation | Replacement Element(s) |
GXSV65 F | FQSVF |
GQSV65 F | FQSVF |
GNSV70 FBL | FQSVF |
GNSV75 FWW | FQSVF |
Manufacturer: General Electric Company
The water treatment device(s) listed on this certificate have met the testing requirements pursuant to Section
116830 of the Health and Safety Code for the following health related contaminants:
Microbiological Contaminants and Turbidity | Inorganic/Radiological Contaminants | |||
Cysts |
| Asbestos |
| |
Turbidity |
| Lead |
| |
Organic Contaminants |
| Mercury |
| |
|
|
| ||
Atrazine |
|
|
| |
Lindane |
|
|
| |
Benzene |
|
|
| |
VOCs | Endrin |
| Simazine | |
Alachlor |
| |||
Atrazine | Ethylbenzene |
| Styrene | |
EDB |
| |||
Benzene |
| |||
Haloacetonitriles (HAN) | ||||
Carbofuran | Bromochloroacetonitrile | Tetrachloroethylene | ||
Carbon Tetrachloride | Dibromoacetonitrile | Toluene | ||
Chlorobenzene | Dichloroacetonitrile | |||
Chloropicrin | Trichloroacetonitrile | Tribromoacetic Acid | ||
Haloketones (HK) |
| |||
DBCP | ||||
Heptachlor |
| |||
Heptachlor Epoxide |
| Trichloroethylene | ||
Hexachlorobutadiene | Trihalomethanes (THMs) | |||
Hexachlorocyclopentadiene | Bromodichloromethane | |||
Lindane |
| Bromoform | ||
Methoxychlor |
| |||
| Chloroform | |||
Pentachlorophenol |
| |||
|
| Chlorodibromomethane | ||
|
| Xylenes | ||
Dinoseb |
|
|
| |
|
|
| ||
Rated Service Capacity: 160 gal |
| Rated Service Flow: 0.6 gpm |
Do not use where water is microbiologically unsafe or with water of unknown quality, except that systems certified for cyst reduction may be used on disinfected waters that may contain filterable cysts.
IOWA RESIDENTS ONLY:
Store or Seller’s Name
Address
City | State | Zip | Telephone |
|
|
|
|
Seller’s signature |
|
|
|
|
|
|
|
Customer’s signature |
| Date |
|
4