GE GXSL55R owner manual SmartWater Filtration System GXSV65R Using Filter Fqsvf, Particulate

Models: GXSV65R GXSL55R

1 48
Download 48 pages 40.45 Kb
Page 6
Image 6

Performance Data Sheet.

SmartWater Filtration System GXSV65R Using Filter FQSVF

This System has been tested according to NSF/ANSI 42 and 53 for the reduction of the substances listed below. The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system, as specified in NSF/ANSI 42 and 53.

Actual performance may vary with local water conditions.

WARNING: Do not use with water that is microbiologically unsafe or with water of unknown quality without adequate disinfection before or after the system. Systems certified for cyst reduction may be used on disinfected waters that may contain filterable cysts.

Standard No. 42: Aesthetic Effects

 

USEPA

Influent

Influent

Effluent

 

 

% Reduction

Maximum Permissible

 

 

 

 

 

Product Water

Parameter

MCL

Challenge Concentration

Average

Average

Maximum

Average

Minimum

Concentration

Chlorine

2.0 mg/L + 10%

2.00 mg/L

<0.05 mg/L

<0.05 mg/L

>97.50%

>97.50%

>50%

T & O

Particulate**

> 10,000 particles/mL

4,100,000 #/mL

76,500 #/mL

110,000 #/mL

98.10%

97.30%

>85%

 

 

 

Standard No. 53: Health Effects

 

 

 

 

Turbidity

0.5 NTU***

11 + 1 NTU***

11.00 NTU

0.1 NTU

0.1 NTU

98.80%

98.20%

0.5 NTU

Cysts

99.95% red.

Min. 50,000/L

140,000 #/L

1 #/L

1 #/L

>99.99%

>99.99%

99.95%

Asbestos

99% red.

280 MF/L

<0.17 MF/L

<0.17 MF/L

>99.00%

>99.00%

99%

Lead, pH 6.5

0.010 mg/L

0.15 mg/L + 10%

0.150 mg/L

<0.001 mg/L

<0.001 mg/L

>99.30%

>99.30%

0.01 mg/L

Lead, pH 8.5

0.010 mg/L

0.15 mg/L + 10%

0.140 mg/L

<0.001 mg/L

<0.001 mg/L

>99.30%

>99.30%

0.01 mg/L

Mercury, pH 6.5

0.002 mg/L

0.006 mg/L ± 10%

0.0065 mg/L

<0.0002 mg/L

<0.0002 mg/L

96.60%

>96.70%

0.002 mg/L

Mercury, pH 8.5

0.002 mg/L

0.006 mg/L ± 10%

0.0059 mg/L

<0.0002 mg/L

<0.0002 mg/L

96.60%

>96.70%

0.002 mg/L

Lindane

0.0002 mg/L

0.002 mg/L ± 10%

0.00193 mg/L

<0.00002 mg/L

0.00005 mg/L

>98.80%

98.80%

0.0002 mg/L

Benzene

0.001 mg/L

0.015 mg/L ± 10%

0.014 mg/L

<0.0005 mg/L

<0.0005 mg/L

>96.40%

>96.40%

0.005 mg/L

Atrazine

0.003 mg/L

0.009 mg/L ± 10%

0.00873 mg/L

<0.0005 mg/L

<0.0005 mg/L

>94.10%

>94.10%

0.003 mg/L

VOC Reduction

 

 

 

 

 

 

 

 

Chloroform

0.080 mg/L

0.300 ± 10%

0.340 mg/L

0.00098 mg/L

0.00620 mg/L

97.90%

98.20%

95%

*Tested using a flow rate of 0.60 gpm (2.27 l/min); pressure of 60 psig; pH of 7.5 ± 0.5; temp. of 68° ± 5°F (20° ± 3°C) **Measurement in particles/mL. Particles used were 0.5–1 microns.

***NTU—Nephelometric Turbidity Units / NTU—unités de turbidité néphélométrique

Operating Specifications / Spécifications d’opération Capacity: certified for up to 160 gallons (605 l); up to six months

Pressure requirement: 35–120 psi (2.8–8.2 bar)

Temperature: 33–100°F (0.6–38°C)

Flow rate: 0.60 gpm (2.27 l/min)

Replacement Filter Canisters/Estimated Replacement Costs

FQSVF—Replacement filter canister $35–40

For replacement parts, call toll-free 800.626.2002 (U.S.), 800.663.6060 (Canada–English), 800.361.3869 (Canada–French)

6

Page 6
Image 6
GE GXSL55R owner manual SmartWater Filtration System GXSV65R Using Filter Fqsvf, Particulate