5 4-Wire Power Cord Installation

5 4-Wire Power Cord Installation

BeforeWARNING: The neutral wire of the supply circuit is connected to the neutral terminal located in the center of the connector block. The power leads must be connected to the outside (brass colored) terminals. The 4th grounding lead must be connected

to the frame of the range with the grounding plate and grounding screw.

a Remove the 3 screws from the connector block.

b

Remove the grounding screw and strap from the connector block middle

location and the screw connection to the frame of the range.

 

 

Insert screws through each power cord terminal ring and into connector

c

block until screw engages nut. Be certain that the center wire is connected

 

 

to the center screw of the connector block. Tighten screws securely.

 

Attach ground wire to the frame of the range.

d

 

Before

After

 

 

Neutral terminal

Neutral terminal

 

 

 

 

Grounding

 

 

 

Ground Strap

plate

 

 

 

 

 

 

 

(grounding to range)

Grounding to range

 

 

 

 

Safety Information Operating Instructions Installation Instructions Troubleshooting Tips Customer Service

33

Page 33
Image 33
GE JBP46, JBP47, JBP45 owner manual 5 4-Wire Power Cord Installation, Before, After