JKP90SP
GE® 27" Built-In Double Microwave/Thermal Wall Oven
Dimensions and Installation Information (in inches)
KW Rating
240V | 6.4 |
|
|
208V | 4.8 |
|
|
Breaker Size | |
|
|
240V | 30 Amps |
|
|
208V | 30 Amps |
|
|
Note: Cabinets installed adjacent to wall ovens must have an adhesion spec of at least a 194°F temperature rating.
Note: if marks, blemishes or the cutout opening is visible above the installed oven, it may be necessary to add wood shims under the runners and front trim until the marks or openings are covered.
Note: Door handle protrudes 3" from door face. Cabinets and drawers on adjacent 45° and 90° walls should be placed to avoid interference with the handle.
Electric wall ovens are not approved for installation with a plug and receptacle. They must be hard wired in accordance with installation instructions.
10
L |
| Recommended |
| junction box | |
C | 2 x 4 or | locations. |
| equivalent | |
| runners | Locate junction |
|
| box either 5" MIN. |
|
| below cutout |
|
| floor or 48" MIN. |
|
| above cutout |
|
| floor |
| Suitable |
|
|
|
|
|
|
| D |
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
| ||
| bracing | 18" |
|
|
|
|
| ||
| to support |
|
|
|
|
| |||
|
| over centerline |
|
|
|
| |||
|
|
|
|
|
| ||||
| runners |
|
|
|
|
|
| ||
|
| of cabinet |
|
| Access |
| |||
| (must support 275 lbs.) |
| |||||||
|
|
|
|
|
|
|
| from |
|
|
|
|
|
|
|
|
| adjacent |
|
|
|
|
|
|
|
|
| cabinet |
|
|
|
|
|
|
|
| required |
| |
| Cabinet |
|
|
|
| 27" |
| ||
| A – Cabinet width required |
|
| 27" min. |
|
| |||
| B – Minimum cabinet depth |
| Minimum | E | |||||
| C – Opening width |
|
|
|
| 25" min. - | cutout location | ||
| D – Opening height |
|
|
|
|
| from floor |
| |
| E – Minimum cutout location from floor |
| 22" |
|
| ||||
| Oven |
|
|
|
|
|
|
|
|
| F – Overall depth* |
|
|
|
|
|
| ||
| G – Overall height with trim |
| 43" - |
|
| ||||
| Overall height without trim |
|
|
| |||||
| H – Overall width |
|
|
|
|
|
|
*Depth including door handle is approximately
A
Allow 3/4" for overlap of oven over all
edges of cutout
C
2" X 4" or
Bequiv. runners H
G
21
Conduit
long) F
Allow minimum of 21" for clearance to adjacent corners, drawers, walls, etc.
Installation Information: Before installing, consult
installation instructions packed with product for current dimensional data.
Note: These ovens are not approved for stackable or
For answers to your Monogram,® GE Profile™ or GE® appliance questions, visit our website at ge.com or call GE Answer Center® service, 800.626.2000.
All GE ranges are equipped with | Listed by |
an | |
of this device is an important, | Underwriters |
required step in the installation | Laboratories |
of the range. |
|
Specification Created 5/09 | 320359 |